JOURNAL ARTICLE
OBSERVATIONAL STUDY
Add like
Add dislike
Add to saved papers

Evaluation of Fixation for Distal Humeral Diaphyseal Fracture by Locking Compression Plate.

Treatment of extra-articular distal humeral shaft fractures with plating techniques is often difficult. The recent development of LCP has improved the surgical treatment of fractures by overcoming the few drawbacks of older fixators. The aim of this prospective observational study was to assess the effectiveness of osteosynthesis of extra-articular diaphyseal fractures of the distal third of the humerus using a single locking compression plate (LCP) and was conducted from July 2016 to June 2018 at the National Institute of Traumatology and Orthopedic Rehabilitation (NITOR), Dhaka, Bangladesh. Thirty (30) patients with closed fracture distal 3rd extra-articular humeral shaft fractures were treated by open reduction and internal fixation by locking compression plate. Two cases were excluded from the evaluation of final outcome due to their discontinued follow up. Detailed clinical conditions of all patients, technical difficulty with the implant, postoperative hospital stay period were recorded. Patients were followed up at 2nd week, 4th week, then 4 weekly upto 6 months. The patients were evaluated clinically and radiologically for outcomes. The progresses of healing as well as occurrence of complications were recorded. The range of motion of the shoulder and elbow were evaluated according to the criteria by Rommens grading. Functional evaluation was made according to the criteria by Modified Constant and Murley Scoring System. Union was achieved in all the patients after a mean of 15 weeks (range 12-20 weeks). There were no complications like deep infection, nonunion, malunion, implant failure, or nerve injury occurs in any of the patients. Two patients had transient radial nerve palsy. Two patients developed superficial infection. All patients were relieved pain postoperatively. Functional outcome were excellent in 10 patients, good in 15 patients which constituted 89% satisfactory results. The study has shown that the LCP is an effective, dependable solution for the management of distal third diaphyseal fractures of the humerus.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app