Monte Carlo dose verification for a single-isocenter VMAT plan in multiple brain metastases

Kento Hoshida, Fujio Araki, Takeshi Ohno, Hirofumi Tominaga, Kazuki Komatsu, Kentaro Tamura
Medical Dosimetry: Official Journal of the American Association of Medical Dosimetrists 2019 February 6
30738651
The purpose of this study was to verify the accuracy of dose calculation algorithms of a treatment planning system for a single-isocenter volumetric modulated arc therapy (VMAT) plan in multiple brain metastases, by comparing the dose distributions of treatment planning system with those of Monte Carlo (MC) simulations. We used a multitarget phantom containing 9 acrylic balls with a diameter of 15.9 mm inside a Lucy phantom measuring 17 × 17 × 17 cm3 . Seven VMAT plans were created using the multitarget phantom: 1 multitarget plan (MTP) and 6 single target plans (STP). Three of the STP plans had a large jaw field setting, almost equivalent to that of the MTP, while the other plans had a jaw field setting fitted to each planning target volume. The isocenter for all VMAT plans was set to the center of the phantom. The VMAT dose distributions were calculated using the analytical anisotropic algorithm (AAA) and were also recalculated through Acuros XB (AXB) and MC simulations under the same irradiation conditions. The AAA and AXB methods tended to overestimate dosage compared with the MC method in the MTP and in STPs with large jaw field settings. The dose distribution in single-isocenter VMAT plans for multiple brain metastases was influenced by jaw field settings. Finally, we concluded that MC-VMAT dose calculations are useful for 3D dose verification of single-isocenter VMAT plans for multiple brain metastases.

Comments

You need to log in or sign up for an account to be able to comment.

No comments yet, be the first to post one!

Trending on Read

Available on the App Store

Available on the Play Store
Remove bar
Read by QxMD icon Read
30738651
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"