We have located links that may give you full text access.
The colonization rate of needleless connector and the impact of disinfection for 15 s on colonization: A prospective pre- and post-intervention study.
Journal of Vascular Access 2019 Februrary 6
PURPOSE:: The optimal scrubbing time for the disinfection of the surface of needleless connectors has not been determined. The evidence for successful needleless connector decontamination with 70% isopropyl alcohol ranges from 5 to 60 s. The aim of this prospective study was to identify colonization on the external surface of needleless connectors on central venous catheters and measure the efficiency of 15 s of scrubbing with 70% alcohol.
METHOD:: A total of 31 patients were included. Samples were collected adhering to aseptic no-touch technique policies. Two samples were collected from the injectable surface of the needleless connector with sterile sodium chloride 0.9% moistened and a dry swab from the same site. Then the surface was scrubbed with alcohol 70% for 15 s for disinfection and second couples of samples for the cultures were taken after disinfection.
FINDINGS:: A total of 420 swabs were obtained. The number of colonization (equal or higher than 15 CFU/plate) was present on 21 of the needleless connectors (20.0%). Coagulase-negative staphylococci was responsible for all the colonization. After disinfection for 15 s, no isolation exceeding 1 CFU/plate was present.
CONCLUSION:: Scrubbing for 15 s with 70% alcohol was found to be successful at elimination of colonization of the surface of needleless connector even in high microorganism counts.
METHOD:: A total of 31 patients were included. Samples were collected adhering to aseptic no-touch technique policies. Two samples were collected from the injectable surface of the needleless connector with sterile sodium chloride 0.9% moistened and a dry swab from the same site. Then the surface was scrubbed with alcohol 70% for 15 s for disinfection and second couples of samples for the cultures were taken after disinfection.
FINDINGS:: A total of 420 swabs were obtained. The number of colonization (equal or higher than 15 CFU/plate) was present on 21 of the needleless connectors (20.0%). Coagulase-negative staphylococci was responsible for all the colonization. After disinfection for 15 s, no isolation exceeding 1 CFU/plate was present.
CONCLUSION:: Scrubbing for 15 s with 70% alcohol was found to be successful at elimination of colonization of the surface of needleless connector even in high microorganism counts.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app