We have located links that may give you full text access.
Near-Infrared Indocyanine Green-Enhanced Fluorescence and Evaluation of the Bowel Microperfusion During Robotic Colorectal Surgery: a Retrospective Original Paper.
Surgical Technology International 2019 May 16
BACKGROUND: Leakage of the anastomosis after colorectal surgery is a severe complication, and one of the most important causes is poor vascular supply. However, a microvascular deficit is often not detectable during surgery under white light. Near-infrared indocyanine green (ICG)-enhanced fluorescence may be useful for assessing microvascular deficits and conceivably preventing anastomotic leakage.
OBJECTIVES: This paper presents a preliminary retrospective case series on robotic colorectal surgery. The aim is to evaluate the feasibility, safety and role of near-infrared ICG-enhanced ?uorescence for the intraoperative assessment of peri-anastomotic tissue vascular perfusion.
MATERIALS AND METHODS: From among more than 164 robotic colorectal cases performed, we retrospectively analyzed 28 that were all performed by the same surgeon (PCG) using near-infrared ICG-enhanced fluorescence technology: 16 left colectomies (57.1%), 8 rectal resections (28.6%), 3 right colectomies (10.8%) and 1 pancolectomy (3.6%).
RESULTS: The rates of conversion, intraoperative complications, dye allergic reaction and mortality were all 0%. In two cases (7.1%)-1 left and 1 right colectomy-the level of the anastomosis was changed intraoperatively after ICG showed ischemic tissues. Despite the application of ICG, one anastomotic leak (after left colectomy for a chronic recurrent sigmoid diverticulitis with pericolic abscess) was observed.
CONCLUSIONS: ICG technology may help to determine when to intraoperatively change the anastomotic level to a safer location. In our case series, ICG results led to a change in the level of the anastomosis in 7.1% of the cases. Despite the use of ICG, we observed one leak. This may have been related to vascularization-independent causes (e.g., infection in this case) or may reflect a need for better standardization of this ICG technology. In particular, we need a way to objectively assess the ICG signal and the related risk of leakage. More randomized, prospective, well-powered trials are needed to unveil the full potential of this innovative surgical technology.
OBJECTIVES: This paper presents a preliminary retrospective case series on robotic colorectal surgery. The aim is to evaluate the feasibility, safety and role of near-infrared ICG-enhanced ?uorescence for the intraoperative assessment of peri-anastomotic tissue vascular perfusion.
MATERIALS AND METHODS: From among more than 164 robotic colorectal cases performed, we retrospectively analyzed 28 that were all performed by the same surgeon (PCG) using near-infrared ICG-enhanced fluorescence technology: 16 left colectomies (57.1%), 8 rectal resections (28.6%), 3 right colectomies (10.8%) and 1 pancolectomy (3.6%).
RESULTS: The rates of conversion, intraoperative complications, dye allergic reaction and mortality were all 0%. In two cases (7.1%)-1 left and 1 right colectomy-the level of the anastomosis was changed intraoperatively after ICG showed ischemic tissues. Despite the application of ICG, one anastomotic leak (after left colectomy for a chronic recurrent sigmoid diverticulitis with pericolic abscess) was observed.
CONCLUSIONS: ICG technology may help to determine when to intraoperatively change the anastomotic level to a safer location. In our case series, ICG results led to a change in the level of the anastomosis in 7.1% of the cases. Despite the use of ICG, we observed one leak. This may have been related to vascularization-independent causes (e.g., infection in this case) or may reflect a need for better standardization of this ICG technology. In particular, we need a way to objectively assess the ICG signal and the related risk of leakage. More randomized, prospective, well-powered trials are needed to unveil the full potential of this innovative surgical technology.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app