Effect of platform switching on peri-implant bone: A 3D finite element analysis.
Journal of Prosthetic Dentistry 2019 January 31
STATEMENT OF PROBLEM: A consensus regarding the effects of platform switching on peri-implant marginal bone levels is lacking. Finite element studies have reported contradictory results.
PURPOSE: The purpose of this finite element analysis study was to evaluate stress distribution in platform-switched (PS) and platform-matched (PM) implants and their surrounding bone.
MATERIAL AND METHODS: An implant (4.5×11 mm) was modeled and screwed into a human mandibular bone block using a computer-aided design (CAD) software program. Two separate models were generated: (1) PM, 4.5-mm implant with 4.5-mm-wide abutment and (2) PS, 4.5-mm implant with 3.5-mm-wide abutment. Implant components were modeled with linear isotropic properties and bones with anisotropic properties. Vertical (200 to 800 N) and oblique (50 to 150 N) forces were applied to each model to simulate occlusal loads. Linear elastic analysis was performed using ANSYS Workbench 16. von Mises equivalent stresses in the implant assemblies and peri-implant bone were calculated and compared with independent samples t test (α=.05).
RESULTS: von Mises equivalent stress values under simulated axial and nonaxial occlusal loads were lower for PM than for PS implant assemblies. However, the differences were not statistically significant. Stress within the peri-implant bone was significantly higher for the PM group than for the PS group (P<.001).
CONCLUSIONS: Platform switching decreased stress within peri-implant bone and may help limit marginal bone resorption.
PURPOSE: The purpose of this finite element analysis study was to evaluate stress distribution in platform-switched (PS) and platform-matched (PM) implants and their surrounding bone.
MATERIAL AND METHODS: An implant (4.5×11 mm) was modeled and screwed into a human mandibular bone block using a computer-aided design (CAD) software program. Two separate models were generated: (1) PM, 4.5-mm implant with 4.5-mm-wide abutment and (2) PS, 4.5-mm implant with 3.5-mm-wide abutment. Implant components were modeled with linear isotropic properties and bones with anisotropic properties. Vertical (200 to 800 N) and oblique (50 to 150 N) forces were applied to each model to simulate occlusal loads. Linear elastic analysis was performed using ANSYS Workbench 16. von Mises equivalent stresses in the implant assemblies and peri-implant bone were calculated and compared with independent samples t test (α=.05).
RESULTS: von Mises equivalent stress values under simulated axial and nonaxial occlusal loads were lower for PM than for PS implant assemblies. However, the differences were not statistically significant. Stress within the peri-implant bone was significantly higher for the PM group than for the PS group (P<.001).
CONCLUSIONS: Platform switching decreased stress within peri-implant bone and may help limit marginal bone resorption.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app