We have located links that may give you full text access.
Time to achieve desired fraction of inspired oxygen using a T-piece ventilator during resuscitation of preterm infants at birth.
Resuscitation 2019 March
AIM: To determine the time between adjustment of FiO2 at the oxygen blender and the desired FiO2 reaching the preterm infant during respiratory support at birth.
METHODS: This observational study was performed using a Neopuff™ T-piece Resuscitator attached to either a test lung (during initial bench tests) or a face mask during the stabilization of infants at birth. FiO2 was titrated following resuscitation guidelines. The duration for the desired FiO2 to reach either the test lung or face mask was recorded, both with and without leakage. A respiratory function monitor was used to record FiO2 and amount of leak.
RESULTS: In bench tests, the median (IQR) time taken to achieve a desired FiO2 was 34.2 (21.8-69.1) s. This duration was positively associated with the desired FiO2 difference, the direction of titration (upwards) and the occurrence of no leak (R2 0.863, F 65.016, p < 0.001). During stabilization of infants (median (IQR) gestational age 29+0 (28+2 -30+0 ) weeks, birthweight 1290 (1240-1488) g), the duration (19.0 (0.0-57.0) s) required to reach a desired FiO2 was less, but still evident. In 27/55 (49%) titrations, the desired FiO2 was not achieved before the FiO2 levels were again changed.
CONCLUSION: There is a clear delay before a desired FiO2 is achieved at the distal end of the T-piece resuscitator. This delay is clinically relevant as this delay could easily lead to over- and under titration of oxygen, which might result in an increased risk for both hypoxia and hyperoxia.
METHODS: This observational study was performed using a Neopuff™ T-piece Resuscitator attached to either a test lung (during initial bench tests) or a face mask during the stabilization of infants at birth. FiO2 was titrated following resuscitation guidelines. The duration for the desired FiO2 to reach either the test lung or face mask was recorded, both with and without leakage. A respiratory function monitor was used to record FiO2 and amount of leak.
RESULTS: In bench tests, the median (IQR) time taken to achieve a desired FiO2 was 34.2 (21.8-69.1) s. This duration was positively associated with the desired FiO2 difference, the direction of titration (upwards) and the occurrence of no leak (R2 0.863, F 65.016, p < 0.001). During stabilization of infants (median (IQR) gestational age 29+0 (28+2 -30+0 ) weeks, birthweight 1290 (1240-1488) g), the duration (19.0 (0.0-57.0) s) required to reach a desired FiO2 was less, but still evident. In 27/55 (49%) titrations, the desired FiO2 was not achieved before the FiO2 levels were again changed.
CONCLUSION: There is a clear delay before a desired FiO2 is achieved at the distal end of the T-piece resuscitator. This delay is clinically relevant as this delay could easily lead to over- and under titration of oxygen, which might result in an increased risk for both hypoxia and hyperoxia.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
The Effect of Albumin Administration in Critically Ill Patients: A Retrospective Single-Center Analysis.Critical Care Medicine 2024 Februrary 8
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app