We have located links that may give you full text access.
Primary replacement for the management of exposed orbital implant.
Orbit 2019 Februrary 2
PURPOSE: We present a series of primary orbital implant replacement for cases of implant exposure to describe our experience of this one-staged surgical approach.
METHODS: This study reports on a one-stage technique which involved the removal of the exposed implant or dermis fat graft (DFG) and insertion of a secondary (replacement) in the same procedure, with a variety of materials, including autologous tissue. Re-exposure in a socket where a DFG was placed was defined as a new defect in the newly epithelialized conjunctiva or dehiscence of the dermis-conjunctiva junction. All cases of primary replacement for the management of exposed orbital implant, porous and non-porous, were included, even when there were clinical signs suggestive of infection. The primary outcome was the rate of re-exposure, requiring additional surgical procedures. Infection following primary replacement was a secondary outcome.
RESULTS: Seventy-eight patients had primary replacement for the management of an exposed orbital implant. 6.4% had re-exposure at a mean follow-up of 49.7 months (9.1% for ball implants and 4.5% for DFG). The rate of exposure was higher in those with prior signs of infection than those without (8% vs. 3.6%). Re-exposure occurred in 4.5% of cases with DFG implantation, 4.3% of cases with non-porous implants and in 20% of cases with porous implants.
CONCLUSION: Primary replacement for management of exposed orbital implant, porous and non-porous, has a high rate of successful outcome even in cases with presumed or confirmed infection.
METHODS: This study reports on a one-stage technique which involved the removal of the exposed implant or dermis fat graft (DFG) and insertion of a secondary (replacement) in the same procedure, with a variety of materials, including autologous tissue. Re-exposure in a socket where a DFG was placed was defined as a new defect in the newly epithelialized conjunctiva or dehiscence of the dermis-conjunctiva junction. All cases of primary replacement for the management of exposed orbital implant, porous and non-porous, were included, even when there were clinical signs suggestive of infection. The primary outcome was the rate of re-exposure, requiring additional surgical procedures. Infection following primary replacement was a secondary outcome.
RESULTS: Seventy-eight patients had primary replacement for the management of an exposed orbital implant. 6.4% had re-exposure at a mean follow-up of 49.7 months (9.1% for ball implants and 4.5% for DFG). The rate of exposure was higher in those with prior signs of infection than those without (8% vs. 3.6%). Re-exposure occurred in 4.5% of cases with DFG implantation, 4.3% of cases with non-porous implants and in 20% of cases with porous implants.
CONCLUSION: Primary replacement for management of exposed orbital implant, porous and non-porous, has a high rate of successful outcome even in cases with presumed or confirmed infection.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now