Reduced Verification of Medication Alerts Increases Prescribing Errors.

OBJECTIVE:  Clinicians using clinical decision support (CDS) to prescribe medications have an obligation to ensure that prescriptions are safe. One option is to verify the safety of prescriptions if there is uncertainty, for example, by using drug references. Supervisory control experiments in aviation and process control have associated errors, with reduced verification arising from overreliance on decision support. However, it is unknown whether this relationship extends to clinical decision-making. Therefore, we examine whether there is a relationship between verification behaviors and prescribing errors, with and without CDS medication alerts, and whether task complexity mediates this.

METHODS:  A total of 120 students in the final 2 years of a medical degree prescribed medicines for patient scenarios using a simulated electronic prescribing system. CDS (correct, incorrect, and no CDS) and task complexity (low and high) were varied. Outcomes were omission (missed prescribing errors) and commission errors (accepted false-positive alerts). Verification measures were access of drug references and view time percentage of task time.

RESULTS:  Failure to access references for medicines with prescribing errors increased omission errors with no CDS (high-complexity: χ 2 (1) = 12.716; p  < 0.001) and incorrect CDS (Fisher's exact; low-complexity: p  = 0.002; high-complexity: p  = 0.001). Failure to access references for false-positive alerts increased commission errors (low-complexity: χ 2 (1) = 16.673, p  < 0.001; high-complexity: χ 2 (1) = 18.690, p  < 0.001). Fewer participants accessed relevant references with incorrect CDS compared with no CDS (McNemar; low-complexity: p  < 0.001; high-complexity: p  < 0.001). Lower view time percentages increased omission ( F (3, 361.914) = 4.498; p  = 0.035) and commission errors ( F (1, 346.223) = 2.712; p  = 0.045). View time percentages were lower in CDS-assisted conditions compared with unassisted conditions ( F (2, 335.743) = 10.443; p  < 0.001).

DISCUSSION:  The presence of CDS reduced verification of prescription safety. When CDS was incorrect, reduced verification was associated with increased prescribing errors.

CONCLUSION:  CDS can be incorrect, and verification provides one mechanism to detect errors. System designers need to facilitate verification without increasing workload or eliminating the benefits of correct CDS.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app