Silver and fluoride content and short-term stability of 38% silver diamine fluoride.
Journal of the American Dental Association 2019 Februrary
BACKGROUND: As silver diamine fluoride (SDF) gains popularity for caries arrest, the authors aimed to investigate the content of fluoride and silver in 38% SDF produced for the US market and its short-term stability.
METHODS: Five samples of 38% SDF were evaluated when the bottle was first opened, and at 7 and 28 days. Fluoride concentrations were determined with a fluoride ion-selective electrode, and silver concentrations were determined with a simultaneous inductively coupled plasma mass spectrometer. pH was measured with a pH probe. Weight and volume of individual drops were measured.
RESULTS: At day 0, 40% of individual measured values were above the expected fluoride concentration, and at day 28, 93% were above the expected fluoride concentration (P = .005). At day 0, 19% of individual measured values were below the lowest expected silver concentration, and at day 28, 93% were below (P < .001). Acidity (pH 10) was consistent over the 3 periods. Mean (standard deviation) weight of a drop was 40 (4.0) milligrams, and mean (standard deviation) volume was 32.55 (1.89) microliters, 30% more than the reported value of 25 μL.
CONCLUSION: Over 28 days, the product pH is stable, whereas the fluoride content tends to increase and the silver content tends to decrease. Drops were larger than expected when dispensed from the bottle.
PRACTICAL IMPLICATIONS: Drops are larger than expected, so each delivers higher than expected quantities of silver and fluoride. Clinicians should exercise caution when using this product on young children, replace the cap immediately, and use as soon as dispensed.
METHODS: Five samples of 38% SDF were evaluated when the bottle was first opened, and at 7 and 28 days. Fluoride concentrations were determined with a fluoride ion-selective electrode, and silver concentrations were determined with a simultaneous inductively coupled plasma mass spectrometer. pH was measured with a pH probe. Weight and volume of individual drops were measured.
RESULTS: At day 0, 40% of individual measured values were above the expected fluoride concentration, and at day 28, 93% were above the expected fluoride concentration (P = .005). At day 0, 19% of individual measured values were below the lowest expected silver concentration, and at day 28, 93% were below (P < .001). Acidity (pH 10) was consistent over the 3 periods. Mean (standard deviation) weight of a drop was 40 (4.0) milligrams, and mean (standard deviation) volume was 32.55 (1.89) microliters, 30% more than the reported value of 25 μL.
CONCLUSION: Over 28 days, the product pH is stable, whereas the fluoride content tends to increase and the silver content tends to decrease. Drops were larger than expected when dispensed from the bottle.
PRACTICAL IMPLICATIONS: Drops are larger than expected, so each delivers higher than expected quantities of silver and fluoride. Clinicians should exercise caution when using this product on young children, replace the cap immediately, and use as soon as dispensed.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app