Continuous Noninvasive Arterial Pressure Monitoring in Obese Patients During Bariatric Surgery: An Evaluation of the Vascular Unloading Technique (Clearsight system).

BACKGROUND: Continuous monitoring of arterial pressure is important in severely obese patients who are at particular risk for cardiovascular complications. Innovative technologies for continuous noninvasive arterial pressure monitoring are now available. In this study, we compared noninvasive arterial pressure measurements using the vascular unloading technique (Clearsight system; Edwards Lifesciences Corp, Irvine, CA) with invasive arterial pressure measurements (radial arterial catheter) in severely obese patients during laparoscopic bariatric surgery.

METHODS: In 35 severely obese patients (median body mass index, 47 kg/m2), we simultaneously recorded noninvasive and invasive arterial pressure measurements over a period of 45 minutes. We compared noninvasive (test method) and invasive (reference method) arterial pressure measurements (sampling rate 1 Hz = 1/s) using Bland-Altman analysis (accounting for multiple measurements per subject), 4-quadrant plot/concordance analysis (2-minute interval, 5 mm Hg exclusion zone), and error grid analysis (calculating the proportions of measurements in risk zones A-E with A indicating no risk, B low risk, C moderate risk, D significant risk, and E dangerous risk for the patient due to the risk of wrong clinical interventions because of measurement errors).

RESULTS: We observed a mean of the differences (±SD, 95% limits of agreement) between the noninvasively and invasively assessed arterial pressure values of 1.1 mm Hg (±7.4 mm Hg, -13.5 to 15.6 mm Hg) for mean arterial pressure (MAP), 6.8 mm Hg (±10.3 mm Hg, -14.4 to 27.9 mm Hg) for systolic arterial pressure, and 0.8 mm Hg (±6.9 mm Hg, -12.9 to 14.4 mm Hg) for diastolic arterial pressure. The 4-quadrant plot concordance rate (ie, the proportion of arterial pressure measurement pairs showing concordant changes to all changes) was 93% (CI, 89%-96%) for MAP, 93% (CI, 89%-97%) for systolic arterial pressure, and 88% (CI, 84%-92%) for diastolic arterial pressure. Error grid analysis showed that the proportions of measurements in risk zones A-E were 89.5%, 10.0%, 0.5%, 0%, and 0% for MAP and 93.7%, 6.0%, 0.3%, 0%, and 0% for systolic arterial pressure, respectively.

CONCLUSIONS: During laparoscopic bariatric surgery, the accuracy and precision of the vascular unloading technique (Clearsight system) was good for MAP and diastolic arterial pressure, but only moderate for systolic arterial pressure according to Bland-Altman analysis. The system showed good trending capabilities. In the error grid analysis, >99% of vascular unloading technique-derived arterial pressure measurements were categorized in no- or low-risk zones.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app