Serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and a single high baseline measurement for swift rule-in: A systematic review and meta-analysis.
European Heart Journal. Acute Cardiovascular Care 2020 Februrary
AIMS: The purpose of this study was to determine (a) the ability of serial high-sensitivity cardiac troponin T measurements to rule out acute myocardial infarction and (b) the ability of a single high baseline high-sensitivity cardiac troponin T measurement to rule in acute myocardial infarction in patients presenting to the emergency department with acute chest pain.
METHODS AND RESULTS: Embase, Medline, Cochrane, Web of Science and Google scholar were searched for prospective cohort studies that evaluated parameters of diagnostic accuracy of serial high-sensitivity cardiac troponin T to rule out acute myocardial infarction and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction. The search yielded 21 studies for the systematic review, of which 14 were included in the meta-analysis, with a total of 11,929 patients and an overall prevalence of acute myocardial infarction of 13.0%. For rule-out, six studies presented the sensitivity of serial measurements <14 ng/l. This cut-off classified 60.1% of patients as rule-out and the summary sensitivity was 96.7% (95% confidence interval: 92.3-99.3). Three studies presented the sensitivity of a one-hour algorithm with a baseline high-sensitivity cardiac troponin T value<12 ng/l and delta 1 hour <3 ng/l. This algorithm classified 60.2% of patients as rule-out and the summary sensitivity was 98.9% (96.4-100). For rule-in, six studies reported the specificity of baseline high-sensitivity cardiac troponin T value>50 ng/l. The summary specificity was 94.6% (91.5-97.1).
CONCLUSION: Serial high-sensitivity cardiac troponin T measurement strategies to rule out acute myocardial infarction perform well, and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction has a high specificity.
METHODS AND RESULTS: Embase, Medline, Cochrane, Web of Science and Google scholar were searched for prospective cohort studies that evaluated parameters of diagnostic accuracy of serial high-sensitivity cardiac troponin T to rule out acute myocardial infarction and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction. The search yielded 21 studies for the systematic review, of which 14 were included in the meta-analysis, with a total of 11,929 patients and an overall prevalence of acute myocardial infarction of 13.0%. For rule-out, six studies presented the sensitivity of serial measurements <14 ng/l. This cut-off classified 60.1% of patients as rule-out and the summary sensitivity was 96.7% (95% confidence interval: 92.3-99.3). Three studies presented the sensitivity of a one-hour algorithm with a baseline high-sensitivity cardiac troponin T value<12 ng/l and delta 1 hour <3 ng/l. This algorithm classified 60.2% of patients as rule-out and the summary sensitivity was 98.9% (96.4-100). For rule-in, six studies reported the specificity of baseline high-sensitivity cardiac troponin T value>50 ng/l. The summary specificity was 94.6% (91.5-97.1).
CONCLUSION: Serial high-sensitivity cardiac troponin T measurement strategies to rule out acute myocardial infarction perform well, and a single baseline high-sensitivity cardiac troponin T value>50 ng/l to rule in acute myocardial infarction has a high specificity.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app