Contractility surrogates derived from three-dimensional lead motion analysis and prediction of acute haemodynamic response to CRT.

Background: Patient-specific left ventricular (LV) lead optimisation strategies with immediate feedback on cardiac resynchronisation therapy (CRT) effectiveness are needed. The purpose of this study was to compare contractility surrogates derived from biventricular lead motion analysis to the peak positive time derivative of LV pressure (dP/dtmax) in patients undergoing CRT implantation.

Methods: Twenty-seven patients underwent CRT implantation with continuous haemodynamic monitoring. The right ventricular (RV) lead was placed in apex and a quadripolar LV lead was placed laterally. Biplane fluoroscopy cine films facilitated construction of three-dimensional RV-LV interlead distance waveforms at baseline and under biventricular pacing (BIVP) from which the following contractility surrogates were derived; fractional shortening (FS), time to peak systolic contraction and peak shortening of the interlead distance (negative slope). Acute haemodynamic CRT response was defined as LV ∆dP/dtmax ≥ 10 %.

Results: We observed a mean increase in dP/dtmax under BIVP (899±205 mm Hg/s vs 777±180 mm Hg/s, p<0.001). Based on ΔdP/dtmax , 18 patients were classified as acute CRT responders and nine as non-responders (23.3%±10.6% vs 1.9±5.3%, p<0.001). The baseline RV-LV interlead distance was associated with echocardiographic LV dimensions (end diastole: R=0.61, p=0.001 and end systole: R=0.54, p=0.004). However, none of the contractility surrogates could discriminate between the acute CRT responders and non-responders (ΔFS: -2.5±2.6% vs - 2.0±3.1%, p=0.50; Δtime to peak systolic contraction: -9.7±18.1% vs -10.8±15.1%, p=0.43 and Δpeak negative slope: -8.7±45.9% vs 12.5±54.8 %, p=0.09).

Conclusion: The baseline RV-LV interlead distance was associated with echocardiographic LV dimensions. In CRT recipients, contractility surrogates derived from the RV-LV interlead distance waveform could not discriminate between acute haemodynamic responders and non-responders.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app