BACKGROUND: Although pulmonary vein isolation (PVI) guided by the ablation index (AI) has been well-developed, acute PV reconnections (PVRs) still occur. This study aimed to compare the prognostic performance of the modified AI and its optimal cut-off value for the prediction of acute PVRs to ensure durable PVI.
METHODS: Three-dimensional left atrium (LA) voltage maps created before an extensive encircling PVI in 64 patients with atrial fibrillation (AF) (45 men, 62 ± 10 years) were examined for an association between electrogram voltage amplitude recorded from the PV-LA junction and acute post-PVI PVRs (spontaneous PVRs and/or ATP-provoked dormant PV conduction).
RESULTS: Acute PVRs were observed in 22 patients (34%) and 33 (3%) of the 1012 PV segments. Acute PVRs were significantly associated with segments with higher bipolar voltage zones (3.23 ± 1.17 vs. 1.97 ± 1.20 mV, P < 0.0001), lower mean AI values (449 [428-450] vs. 460 [437-486], P = 0.05), and radiofrequency lesion gaps ≥ 6 mm (48 vs. 32%, P = 0.04), but not with contact force, force-time integral, or power. We created the modified AI calculated as AI/LA bipolar voltage, and found it to be significantly lower in areas with acute PVRs than in those without (152 [109-185] vs. 256 [176-413] AU/mV, P < 0.0001). Univariate analysis showed the prognostic performance of the modified AI, with an area under the curve of 0.801 (0.775-0.825), to be the highest of all the significant parameters.
CONCLUSIONS: Low values of the novel modified AI on the PV-encircling ablation line were strongly associated with acute PVRs.
METHODS: Three-dimensional left atrium (LA) voltage maps created before an extensive encircling PVI in 64 patients with atrial fibrillation (AF) (45 men, 62 ± 10 years) were examined for an association between electrogram voltage amplitude recorded from the PV-LA junction and acute post-PVI PVRs (spontaneous PVRs and/or ATP-provoked dormant PV conduction).
RESULTS: Acute PVRs were observed in 22 patients (34%) and 33 (3%) of the 1012 PV segments. Acute PVRs were significantly associated with segments with higher bipolar voltage zones (3.23 ± 1.17 vs. 1.97 ± 1.20 mV, P < 0.0001), lower mean AI values (449 [428-450] vs. 460 [437-486], P = 0.05), and radiofrequency lesion gaps ≥ 6 mm (48 vs. 32%, P = 0.04), but not with contact force, force-time integral, or power. We created the modified AI calculated as AI/LA bipolar voltage, and found it to be significantly lower in areas with acute PVRs than in those without (152 [109-185] vs. 256 [176-413] AU/mV, P < 0.0001). Univariate analysis showed the prognostic performance of the modified AI, with an area under the curve of 0.801 (0.775-0.825), to be the highest of all the significant parameters.
CONCLUSIONS: Low values of the novel modified AI on the PV-encircling ablation line were strongly associated with acute PVRs.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app