Journal Article
Validation Study
Add like
Add dislike
Add to saved papers

A validated liquid chromatography/tandem mass spectrometry method for 4,4'-methylenedianiline quantitation in human urine as a measure of 4,4'-methylene diphenyl diisocyanate exposure.

RATIONALE: 4,4'-Methylene diphenyl diisocyanate (MDI) is a highly reactive isocyanate used in the production of polyurethanes. Workers exposed to these products may develop sensitization to the diisocyanate compounds, leading to occupational asthma. Quantifying MDI levels is necessary to ensure workplace safety. MDI is metabolized by acetylation and/or conjugation to macromolecules for excretion into urine. All metabolites can be chemically hydrolyzed to form the free diamine 4,4'-methylenedianiline (MDA) as a urinary biomarker of MDI exposure. Current methods involve long sample preparation, or have been designed using costly automation. There is therefore a need to develop a new practical method for assessing exposure to MDI.

METHODS: Urine samples were acidified and heated to form MDA, followed by neutralization and liquid-liquid extraction. Extracts were separated by reversed-phase chromatography on a HSS T3 column followed by analysis on a triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode.

RESULTS: 13 C15 N-MDA was selected as the internal standard (IS) of choice following an investigation of internal standard stability. The hydrolysis efficiency, forming free MDA from conjugated metabolites in vivo, was evaluated using 4,4'-methylenebis(acetanilide) spiked into urine and complete hydrolysis occurred after 1 h. A dynamic range of 5 to 500 nM was achieved, and was useful for monitoring MDI exposure considering the biological guidance value (BGV) of 10 μg/L (~50 nM) proposed by the German Research Foundation (DFG). The limit of detection (LOD) and limit of quantification (LOQ) of the method were 0.8 and 2.7 nM, respectively. The intra-day and inter-day precisions were 4.33% and 4.27%, respectively. Finally, the method was tested with inter-laboratory samples from the German External Quality Assessment Scheme (G-EQUAS) program and the results submitted were all within the allowable tolerance range.

CONCLUSIONS: A practical and validated method for the analysis of small- to medium-sized batches of samples has been developed for the biological monitoring of MDI exposure in human urine.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app