A 24-hour perioperative case study on argatroban use for left ventricle assist device insertion during cardiopulmonary bypass and veno-arterial extracorporeal membrane oxygenation.

Perfusion 2019 May
A 44-year-old male with ongoing chest pain and left ventricular ejection fraction <20% was transferred from a peripheral hospital with intra-aortic balloon pump placement following a non-ST-elevation myocardial infarction (STEMI). The patient underwent emergent multi-vessel coronary artery bypass grafting requiring veno-arterial (VA) extracorporeal membrane oxygenation (ECMO) on post-operative day (POD)#9 secondary to cardiogenic shock with biventricular failure. Due to clot formation, an oxygenator change-out was necessary shortly after initiation. Following a positive heparin-induced thrombocytopenia (HIT) assay, a total circuit exchange was required to eliminate all heparin coating and argatroban was deemed the anticoagulant of choice due to acute kidney injury. On POD#24, the decision was made to implant a left ventricle assist device (LVAD) as a bridge to heart transplantation. There was difficulty achieving an activated clotting time (ACT) >400 s: multiple argatroban bolus doses were required, along with accelerated up-titration of infusion dosing. Despite maintaining an ACT >484 s, clot formation was observed in the cardiotomy reservoir prior to separation. Subsequently, the patient developed severe disseminated intravascular coagulopathy, with both intra-cardiac and intravascular thrombi, requiring massive transfusion and continuous cell saving due to severe hemorrhage post cardiopulmonary bypass (CPB). The patient received a total of 105 units of plasma, 74 units of packed red cells, 19 units of platelets, 13 bottles of 5% albumin, 6 units of cryoprecipitate and 2 doses of factor VIIa intraoperatively over the course of 24 hours. A total of 19.7 L of washed red blood cells were returned to the patient from the cell saver. With the LVAD in place, the patient developed transfusion-related acute lung injury and acute respiratory distress syndrome with right ventricular dysfunction requiring VA ECMO once again. On POD#30, ECMO was discontinued and the patient was discharged from the intensive care unit (ICU) on POD 66. After a very complex post-operative stay with numerous surgeries and extensive rehabilitation, the patient was discharged home with the LVAD on POD#112.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app