OBJECTIVES: Because data for neonates are limited, optimal management of critical aortic stenosis remains controversial (balloon valvotomy [BV] or open valvoplasty [OV]). In a center with balanced experience in both methods, we hypothesized that OV can provide a better individualized approach than blunt BV and better serve long-term outcomes.
METHODS: A retrospective review of data and follow-up (survival, freedom from operation/replacement) of all neonates, suitable for biventricular repair, undergoing aortic valve procedure (1989-2015), was performed.
RESULTS: One hundred three patients were concomitantly treated (BV [n = 51], OV [n = 52). Median age was 8 days, median aortic annulus Z-score was -1.3 for BV (range, -3.9 to 2.0) and OV (-3.9 to 3.2) groups. Operative mortality after BV or OV was 8% (n = 4) and 4% (n = 2), respectively. With a 13-year median follow-up, 10-year freedom from operation was 36% and 66% after BV or OV, respectively. Valve replacement was ultimately required in 32 patients (n = 20 [39%] in the BV group; n = 12 [23%] in the OV group) within a 5.9-year median time. After OV, tricuspid arrangement of the repaired aortic valve provided a 10-year freedom from operation and replacement of 87% and 95%, respectively. In multivariate analysis, associated left heart malformations, BV, nontricuspid geometry, and inadequate post procedural result were predictive of operation and replacement.
CONCLUSIONS: In neonates with critical aortic stenosis, both methods (BV and OV) offer excellent survival benefit. OV significantly minimizes the need for operation, whereas BV did not postpone age of replacement. Clearly superior results are achieved with OV when a post repair tricuspid arrangement is obtained.
METHODS: A retrospective review of data and follow-up (survival, freedom from operation/replacement) of all neonates, suitable for biventricular repair, undergoing aortic valve procedure (1989-2015), was performed.
RESULTS: One hundred three patients were concomitantly treated (BV [n = 51], OV [n = 52). Median age was 8 days, median aortic annulus Z-score was -1.3 for BV (range, -3.9 to 2.0) and OV (-3.9 to 3.2) groups. Operative mortality after BV or OV was 8% (n = 4) and 4% (n = 2), respectively. With a 13-year median follow-up, 10-year freedom from operation was 36% and 66% after BV or OV, respectively. Valve replacement was ultimately required in 32 patients (n = 20 [39%] in the BV group; n = 12 [23%] in the OV group) within a 5.9-year median time. After OV, tricuspid arrangement of the repaired aortic valve provided a 10-year freedom from operation and replacement of 87% and 95%, respectively. In multivariate analysis, associated left heart malformations, BV, nontricuspid geometry, and inadequate post procedural result were predictive of operation and replacement.
CONCLUSIONS: In neonates with critical aortic stenosis, both methods (BV and OV) offer excellent survival benefit. OV significantly minimizes the need for operation, whereas BV did not postpone age of replacement. Clearly superior results are achieved with OV when a post repair tricuspid arrangement is obtained.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app