We have located links that may give you full text access.
Quantification of rheumatic mitral stenosis severity with three-dimensional vena contracta area.
Echocardiography 2019 Februrary
INTRODUCTION: Rheumatic mitral stenosis (MS) is an important health issue in developing countries. Assessment of the correct mitral valve area (MVA) is essential for the timing of intervention. Most of the parameters for the assessment of rheumatic MS are derived from Two-dimensional (2D) echocardiography. Three-dimensional (3D) echocardiography is commonly used in our daily practice at the present time. The aim of this study was to assess the value of 3D echocardiography mitral valve vena contracta area (VCA) in predicting the severity of Rheumatic MS by comparing 3D planimetry.
METHODS: The patients, who had been diagnosed as mild, moderate, and severe rheumatic MS with conventional methods (pressure half time, planimetry) by 2D transesophageal echocardiography (TEE)/ transthoracic echocardiography (TTE), underwent 3D TEE evaluation. Also, the patients who had an atrial fibrillation and more than moderate aortic regurgitation were included in the study. 3D TEE full volume mitral valve VCA was measured in end-diastole during its largest dimensions. 3D TEE full volume and 3D zoom MVA planimetry were measured at the end-diastole during the mitral valve`s largest opening.
RESULTS: We studied 40 patients (the mean age: 51.1 ± 11.6 years, 31 females) with rheumatic MS. 3D TEE VCA was found to be highly correlated with the 3D TEE MVA (r = 0.82, P < 0.001).
CONCLUSION: Our study findings provide evidence that 3D TEE mitral valve VCA can be additionally used in detecting the severity of rheumatic MS.
METHODS: The patients, who had been diagnosed as mild, moderate, and severe rheumatic MS with conventional methods (pressure half time, planimetry) by 2D transesophageal echocardiography (TEE)/ transthoracic echocardiography (TTE), underwent 3D TEE evaluation. Also, the patients who had an atrial fibrillation and more than moderate aortic regurgitation were included in the study. 3D TEE full volume mitral valve VCA was measured in end-diastole during its largest dimensions. 3D TEE full volume and 3D zoom MVA planimetry were measured at the end-diastole during the mitral valve`s largest opening.
RESULTS: We studied 40 patients (the mean age: 51.1 ± 11.6 years, 31 females) with rheumatic MS. 3D TEE VCA was found to be highly correlated with the 3D TEE MVA (r = 0.82, P < 0.001).
CONCLUSION: Our study findings provide evidence that 3D TEE mitral valve VCA can be additionally used in detecting the severity of rheumatic MS.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app