Add like
Add dislike
Add to saved papers

Is anterior guidance a key factor on planning implant treatment for free-end missing in the posterior mandible?

To perform safe implant treatment, the anatomical structure and bone quality at implant placement sites are evaluated based on a patient's CT data, but there is no definite method to determine placement sites and the appropriate number of implants. The objective of this study was to investigate the influence of the number and arrangement of implants on the stress distribution in 3-unit posterior fixed partial dentures for the posterior mandible by mechanical analysis using the finite element method. Three-dimensional finite element analysis models were constructed from the CT data of a patient with missing mandibular teeth (Nos. 35, 36, 37). Implant placement was simulated under various conditions. Superstructures were connected and fixed with a titanium frame. As the loading conditions, 400 N vertical and lateral loads (45 degrees on the lingual side and 45 degrees on the buccal side) were applied to the upper areas of Nos. 35, 36, and 37, and the stress distribution and frame displacement were evaluated. When a vertical force was applied, no difference of the von Mises stress was noted among the 5 experimental conditions. When lateral force was applied from the lingual and buccal sides at 45 degrees, the stress was higher than that induced by vertical force under all conditions, and it was especially high under mesial and distal cantilever conditions. When displacement of the titanium frame was measured, the displacement caused by lateral force was greater than that due to vertical force. In addition, comparison between long and short distal cantilever bridges revealed that displacement of the titanium frame tended to be smaller when the short cantilever was used. These findings suggested that the stress on peri-implant tissues and displacement of the titanium frame vary depending on the configuration and number of implants, with greater stress and more marked displacement of the titanium frame being induced by lateral force when the number of implants is reduced and a cantilever bridge is selected.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app