Diagnostic Utility of [11C]DTBZ Positron Emission Tomography In Clinically Uncertain Parkinsonism: Experience of a Single Tertiary Center.
Background: The use of single-photon emission computed tomography and positron emission tomography (PET) has proven to be helpful in differentiating Parkinson's disease (PD) from other movement disorders with a sensitivity of up to 95%.
Objective: The objective of this study was to determine the accuracy of [11C]DTBZ PET imaging in patients with clinically uncertain parkinsonism from a tertiary referral center in Mexico City.
Materials and Methods: Patients who underwent [11C]DTBZ PET brain scan due to clinically uncertain parkinsonism where divided into two groups: PD or non-PD. A scan was considered positive when visual assessment revealed a decrease in [11C]DTBZ uptake typical for PD; a scan was considered negative when visual assessment showed no decrease in [11C]DTBZ uptake or showed a decrease in tracer uptake in a non-PD pattern. Sensitivity, specificity, and positive and negative predictive values were calculated using a 2 × 2 table, with a 95% confidence interval.
Results: A total of 39 patients were included in the study. 14 PET studies were deemed positive and 25 PET studies were deemed negative; 12 true positives and 23 true negatives were found. This yielded a sensitivity of 92.9% (95% CI, 66.1-99.8), specificity of 92% (95% CI, 74-99), PPV of 86.7% (95% CI, 63.1-96.1), and NPV of 95.8% (95% CI, 79.1-98.4).
Conclusions: The [11C]DTBZ PET has an excellent accuracy for differentiating idiopathic PD from other disorders.
Objective: The objective of this study was to determine the accuracy of [11C]DTBZ PET imaging in patients with clinically uncertain parkinsonism from a tertiary referral center in Mexico City.
Materials and Methods: Patients who underwent [11C]DTBZ PET brain scan due to clinically uncertain parkinsonism where divided into two groups: PD or non-PD. A scan was considered positive when visual assessment revealed a decrease in [11C]DTBZ uptake typical for PD; a scan was considered negative when visual assessment showed no decrease in [11C]DTBZ uptake or showed a decrease in tracer uptake in a non-PD pattern. Sensitivity, specificity, and positive and negative predictive values were calculated using a 2 × 2 table, with a 95% confidence interval.
Results: A total of 39 patients were included in the study. 14 PET studies were deemed positive and 25 PET studies were deemed negative; 12 true positives and 23 true negatives were found. This yielded a sensitivity of 92.9% (95% CI, 66.1-99.8), specificity of 92% (95% CI, 74-99), PPV of 86.7% (95% CI, 63.1-96.1), and NPV of 95.8% (95% CI, 79.1-98.4).
Conclusions: The [11C]DTBZ PET has an excellent accuracy for differentiating idiopathic PD from other disorders.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app