We have located links that may give you full text access.
COMPARATIVE STUDY
EVALUATION STUDY
JOURNAL ARTICLE
RESEARCH SUPPORT, NON-U.S. GOV'T
Comparative performance of the Biocentric Generic Viral Load, Roche CAP/CTM v1.5, Roche CAP/CTM v2.0 and m2000 Abbott assays for quantifying HIV-1 B and non-B strains: Underestimation of some CRF02 strains.
Journal of Clinical Virology 2019 January
BACKGROUND: HIV-1 viral load testing is now recommended by the World Health Organization for every patient receiving antiretroviral therapy (ART).
OBJECTIVES: The objective of this study is to evaluate the performance of commercial assays for their ability to quantify HIV-1 strains currently circulating in France.
STUDY DESIGN: The performances of the Generic HIV-RNA assay from Biocentric were compared to those of the Roche CAP/CTM v1.5, Roche CAP/CTM v2.0 and Abbott m2000 RealTime HIV-1 assays. A total of 1885 HIV-1 plasma samples were tested, including 684 samples from patients included in the ANRS-Primo Cohort.
RESULTS: We found a good concordance of quantification between the Roche v2.0 and the Biocentric assays, both of which were superior to the Roche v1.5 assay. We show moderate agreement between techniques; however, CRF02_AG strains and undetermined viruses were underestimated when quantified with the Roche CAP/CTM v2.0. In contrast, a comparison of the Biocentric and Abbott assay results showed strong agreement between assays, indicating that both are well suited for quantification of CRF02_AG strains. Moreover, a 2% underestimation of the B subtypes was observed with the Biocentric assay.
CONCLUSIONS: These results have implications for viral load monitoring in Western Africa, where CRF02_AG strains are highly prevalent. Closer epidemiological surveillance and evaluation of commercial assays are still necessary to better evaluate the impact of the genetic evolution of circulating viruses on HIV-RNA quantification in the regions most affected by the HIV-1 epidemic.
OBJECTIVES: The objective of this study is to evaluate the performance of commercial assays for their ability to quantify HIV-1 strains currently circulating in France.
STUDY DESIGN: The performances of the Generic HIV-RNA assay from Biocentric were compared to those of the Roche CAP/CTM v1.5, Roche CAP/CTM v2.0 and Abbott m2000 RealTime HIV-1 assays. A total of 1885 HIV-1 plasma samples were tested, including 684 samples from patients included in the ANRS-Primo Cohort.
RESULTS: We found a good concordance of quantification between the Roche v2.0 and the Biocentric assays, both of which were superior to the Roche v1.5 assay. We show moderate agreement between techniques; however, CRF02_AG strains and undetermined viruses were underestimated when quantified with the Roche CAP/CTM v2.0. In contrast, a comparison of the Biocentric and Abbott assay results showed strong agreement between assays, indicating that both are well suited for quantification of CRF02_AG strains. Moreover, a 2% underestimation of the B subtypes was observed with the Biocentric assay.
CONCLUSIONS: These results have implications for viral load monitoring in Western Africa, where CRF02_AG strains are highly prevalent. Closer epidemiological surveillance and evaluation of commercial assays are still necessary to better evaluate the impact of the genetic evolution of circulating viruses on HIV-RNA quantification in the regions most affected by the HIV-1 epidemic.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app