Mouthguard sheet temperature after heating under pressure former.
Dental Traumatology : Official Publication of International Association for Dental Traumatology 2018 December 8
BACKGROUND/AIM: Ethylene vinyl acetate and polyolefin sheets have been used commonly for fabricating mouthguards. However, the change of the sheet temperature during heating of the polyolefin has not been clarified. The aim of this study was to examine the effects of changing the sheet temperature during heating and to examine whether there were any differences between the sheet materials.
MATERIALS AND METHODS: The mouthguard materials used were 4.0 mm sheets of ethylene vinyl acetate and polyolefin. The sheet temperature of the two materials was measured when the center of the sheet was displaced by 10, 15, and 20 mm from the baseline after heating. The sheets were pressure-formed when the heating temperatures reached 100 °C. Mouthguard thickness and fit was measured at the central incisor and the first molar. Differences in the sheet temperature and the thickness between the sheet materials were analyzed by two-way analysis of variance.
RESULTS: The sheet temperature of ethylene vinyl acetate and polyolefin sheets became higher as the hanging distance became larger (P < 0.01), and there were statistically significant differences between ethylene vinyl acetate and polyolefin sheets at the hanging distance of 10 and 15 mm (P < 0.01). The thicknesses of the pressure-formed mouthguard at the central incisor and the first molar were greater in the mouthguards formed by ethylene vinyl acetate sheets than those with polyolefin sheets (P < 0.01 and P < 0.05, respectively). The fit of the mouthguard was not different between mouthguards formed by ethylene vinyl acetate sheets and those formed by polyolefin sheets.
CONCLUSIONS: The change of mouthguard sheet temperature during heating was different between ethylene vinyl acetate and polyolefin sheets. The ethylene vinyl acetate sheets maintained the mouthguard thickness in comparison with the polyolefin sheets at the same heating temperature. This article is protected by copyright. All rights reserved.
MATERIALS AND METHODS: The mouthguard materials used were 4.0 mm sheets of ethylene vinyl acetate and polyolefin. The sheet temperature of the two materials was measured when the center of the sheet was displaced by 10, 15, and 20 mm from the baseline after heating. The sheets were pressure-formed when the heating temperatures reached 100 °C. Mouthguard thickness and fit was measured at the central incisor and the first molar. Differences in the sheet temperature and the thickness between the sheet materials were analyzed by two-way analysis of variance.
RESULTS: The sheet temperature of ethylene vinyl acetate and polyolefin sheets became higher as the hanging distance became larger (P < 0.01), and there were statistically significant differences between ethylene vinyl acetate and polyolefin sheets at the hanging distance of 10 and 15 mm (P < 0.01). The thicknesses of the pressure-formed mouthguard at the central incisor and the first molar were greater in the mouthguards formed by ethylene vinyl acetate sheets than those with polyolefin sheets (P < 0.01 and P < 0.05, respectively). The fit of the mouthguard was not different between mouthguards formed by ethylene vinyl acetate sheets and those formed by polyolefin sheets.
CONCLUSIONS: The change of mouthguard sheet temperature during heating was different between ethylene vinyl acetate and polyolefin sheets. The ethylene vinyl acetate sheets maintained the mouthguard thickness in comparison with the polyolefin sheets at the same heating temperature. This article is protected by copyright. All rights reserved.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app