OBJECTIVE: This study aimed to assess the safety and feasibility of transcatheter device closure of atrial septal defects (ASDs) guided completely by transthoracic echocardiography (TTE).
METHODS: A total of 152 patients underwent transcatheter device closure of ASDs guided completely by TTE in our center from September 2014 to June 2017. We used routine delivery sheaths during the procedure and then closed the ASDs by releasing a domestic occluder.
RESULTS: The closure was successful in 150 patients, and surgical repair was required in two patients. The size of the deployed occluder ranged from 10 mm to 38 mm (21.4±8.5 mm), and the procedure duration ranged from 30 to 90 min (38.2±21.4 min). No fatal complications were observed. Minor complications included transient arrhythmias (n=12) during the process of device deployment. The follow-up period was 3 months to 2 years, with no occluder dislodgment, residual fistula, or thrombus-related complications. In our comparative studies, no statistically significant differences were observed in success rates and complications.
CONCLUSION: Transcatheter device closure of ASDs guided completely by TTE may be safe and effective and can be an alternative to traditional methods.
METHODS: A total of 152 patients underwent transcatheter device closure of ASDs guided completely by TTE in our center from September 2014 to June 2017. We used routine delivery sheaths during the procedure and then closed the ASDs by releasing a domestic occluder.
RESULTS: The closure was successful in 150 patients, and surgical repair was required in two patients. The size of the deployed occluder ranged from 10 mm to 38 mm (21.4±8.5 mm), and the procedure duration ranged from 30 to 90 min (38.2±21.4 min). No fatal complications were observed. Minor complications included transient arrhythmias (n=12) during the process of device deployment. The follow-up period was 3 months to 2 years, with no occluder dislodgment, residual fistula, or thrombus-related complications. In our comparative studies, no statistically significant differences were observed in success rates and complications.
CONCLUSION: Transcatheter device closure of ASDs guided completely by TTE may be safe and effective and can be an alternative to traditional methods.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app