Predictive Score Model for Delayed Graft Function Based on Hypothermic Machine Perfusion Variables in Kidney Transplantation.

Chinese Medical Journal 2018 November 21
Background: Hypothermic machine perfusion (HMP) is being used more often in cardiac death kidney transplantation; however, the significance of assessing organ quality and predicting delayed graft function (DGF) by HMP parameters is still controversial. Therefore, we used a readily available HMP variable to design a scoring model that can identify the highest risk of DGF and provide the guidance and advice for organ allocation and DCD kidney assessment.

Methods: From September 1, 2012 to August 31, 2016, 366 qualified kidneys were randomly assigned to the development and validation cohorts in a 2:1 distribution. The HMP variables of the development cohort served as candidate univariate predictors for DGF. The independent predictors of DGF were identified by multivariate logistic regression analysis with a P < 0.05. According to the odds ratios (ORs) value, each HMP variable was assigned a weighted integer, and the sum of the integers indicated the total risk score for each kidney. The validation cohort was used to verify the accuracy and reliability of the scoring model.

Results: HMP duration (OR = 1.165, 95% confidence interval [CI]: 1.008-1.360, P = 0.043), resistance (OR = 2.190, 95% CI: 1.032-10.20, P < 0.001), and flow rate (OR = 0.931, 95% CI: 0.894-0.967, P = 0.011) were the independent predictors of identified DGF. The HMP predictive score ranged from 0 to 14, and there was a clear increase in the incidence of DGF, from the low predictive score group to the very high predictive score group. We formed four increasingly serious risk categories (scores 0-3, 4-7, 8-11, and 12-14) according to the frequency associated with the different risk scores of DGF. The HMP predictive score indicates good discriminative power with a c-statistic of 0.706 in the validation cohort, and it had significantly better prediction value for DGF compared to both terminal flow (P = 0.012) and resistance (P = 0.006).

Conclusion: The HMP predictive score is a good noninvasive tool for assessing the quality of DCD kidneys, and it is potentially useful for physicians in making optimal decisions about the organs donated.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app