We have located links that may give you full text access.
CASE REPORTS
COMPARATIVE STUDY
JOURNAL ARTICLE
Off-Pump Plicating Ascending Aortoplasty With External Wrapping: Magnum in Parvo.
Heart, Lung & Circulation 2019 December
BACKGROUND: Isolated, fusiform aneurysms, exclusively affecting the tubular portion of the ascending aorta, are rare. Surgical treatment aims to change their natural course, reducing individual and cumulative risks of rupture, dissection and death. Open tubular graft replacement still remains the procedure of choice, despite significant risks. In permanent pursuit for optimal, alternative surgical strategy in high-risk patients, less invasive and off-pump plicating ascending aortoplasty with modified external Dacron graft wrapping seems to be a reliable choice.
METHODS: Two (2) consecutive patients were operated on. The same preoperative calculations and slightly different operative techniques were applied regarding surgical exposure and wrapping graft orientation. Immediate and late follow-up (5 years) results were compared.
RESULTS: Absolute and indexed target ascending aortic diameters remained acceptable (<2.1cm/m2 considered the upper normal range for adults). There were no significant changes in proximal and distal aortic diameters. Ascending aortic silhouette on contrast enhanced multi-detector CT was better with Dacron wrapping graft tailored to have its grooves in the longitudinal direction. Upper mini-sternotomy was quite appropriate for this procedure, from a surgical point of view, and was safe for the patient.
CONCLUSIONS: Careful patient selection and using the current model of preoperative calculations and surgical technique resulted in acceptable and stable ascending aortoplasty in high-risk patients 5 years after surgery.
METHODS: Two (2) consecutive patients were operated on. The same preoperative calculations and slightly different operative techniques were applied regarding surgical exposure and wrapping graft orientation. Immediate and late follow-up (5 years) results were compared.
RESULTS: Absolute and indexed target ascending aortic diameters remained acceptable (<2.1cm/m2 considered the upper normal range for adults). There were no significant changes in proximal and distal aortic diameters. Ascending aortic silhouette on contrast enhanced multi-detector CT was better with Dacron wrapping graft tailored to have its grooves in the longitudinal direction. Upper mini-sternotomy was quite appropriate for this procedure, from a surgical point of view, and was safe for the patient.
CONCLUSIONS: Careful patient selection and using the current model of preoperative calculations and surgical technique resulted in acceptable and stable ascending aortoplasty in high-risk patients 5 years after surgery.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app