We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
3.0T Contrast-enhanced whole-heart coronary magnetic resonance angiography for simultaneous coronary artery angiography and myocardial viability in chronic myocardial infarction: A single-center preliminary study.
Medicine (Baltimore) 2018 November
To evaluate the accuracy of contrast-enhanced whole-heart magnetic resonance coronary angiography at 3.0T for assessing significant stenosis (≥50% lumen diameter reduction) in patients with myocardial infarction, by using conventional coronary artery angiography as the reference standard, and also test the performance of that for the detection and assessment of chronic myocardial infarction (MI), compared with standard delayed-enhancement coronary magnetic resonance (DE-CMR) for the determination of infarct size.We studied 42 consecutive patients (37 men, 5 women, mean age 58.5 ± 10.7 years) with MI scheduled for conventional coronary angiography. Contrast-enhanced whole-heart coronary magnetic resonance angiography (CMRA) was employed after sublingual nitroglycerin (NTG) with the abdominal banding rolled tightly along the side of ribs. Finally, a 3D phase-sensitive inversion-recovery gradient-echo (3D-PSIR-GRE) sequence was performed during free breathing. The assessment of MI sizes on WH-CMRA reconstructed images and 3D-PSIR-GRE images were compared using a paired student t test.The acquisition of CMRA was completed in 40 (95.2%) of 42 patients, with an imaging time averaged at 9.5 ± 3.1 minutes. The average navigator efficiency was 47%. The sensitivity, specificity, and positive and negative predictive values of whole-heart CMRA for the detection of significant lesions on a segment-by-segment analysis were 91.7% (95% confidence interval [CI] 83.8-96.1), 84.0% (95% CI 80.0-87.4), 57.9% (95% CI 50.0-65.8), 97.7% (95% CI 95.3-98.9), respectively, and on a patient-based analysis 93.5% (95% CI 77.2-98.9), 88.9% (95% CI 50.7-99.4), 96.7% (95% CI 80.9-99.8), and 80.0% (95% CI 44.2-96.5), respectively. Infarcts were generally higher on the CE-CMRA technique compared with the standard technique (18.0 ± 7.2 cm vs 16.1 ± 6.4 cm; P < .0001).Contrast-enhanced whole-heart CMRA with 3.0-T not only may permit reliable detection of significant obstructive coronary artery disease in patients with myocardial infarction, but also could identify and quantify the volume of myocardial infarction. This technique could be considered the preferred approach in patients who could not overcome longer scanning times or unable to hold their breath instead of delayed-enhancement magnetic resonance imaging for detection of infarcted myocardium. However, compared with standard imaging, the volume of myocardial infarction is slightly overestimated.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app