Iodine contrast agents do not influence Platelet-Rich Plasma function at an early time point in vitro.

BACKGROUND: Iodine contrast agents (ICAs) are routinely used by radiologists to help guide intra-articular infiltrations. The aim of this study was to assess the in vitro effects of ICA on platelet function of human autologous Platelet-Rich Plasma (PRP).

METHODS: One hundred thirty-seven consecutive patients with symptomatic femoral-patellar osteoarthritis were included. All were addressed to our institution for a fluoroscopy-guided intra-articular PRP infiltration of the pathological femoral-patellar joint. For each patient, 500 μl of PRP were sampled before intra-articular injection. First, PRP samples were mixed with 50 μl of 2 widely used ICA: Visipaque270® (Iodixanol, n = 58) and Iopamiron200® (Iopamidol, n = 69). PRP concentration ([PRP]) was measured at different delays of incubation (t = 0, 5, 10, 15, 20 and 30 min) enabling to calculate PRP ratio (defined as [PRP](t)/[PRP](0mn)) at each delay, for each mixture, in order to quantitatively assess the influence of ICA on PRP ratio. Second, the PRP samples of 10 additional patients were mixed with Visipaque270®, Visipaque270®, Iopamiron200® and phosphate buffer saline (PBS: control solution) in order to qualitatively assess the influence of ICA on platelet aggregation, using ADP, Collagen, Arachidonic acid and TRAP tests. The surface expression of human P-selectin, a marker of α-granule release, in the PRP + Visipaque270® and PRP + Iopamiron200® mixtures was finally compared. Repeated-measures ANOVA, classical 2-way ANOVA and Wilcoxon matched-pairs test were used to study the influence of ICA on PRP quality.

RESULTS: There was no significant change in PRP ratio during the first 30mn of incubation (p = 0.991) whatever the ICA (p = 0.926). Whatever the aggregation test, there was no significant difference in the percentage of platelet aggregation between PRP + PBS, PRP + Visipaque270® and PRP + Iopamiron200® (p = 0.998), nor between PRP + PBS and PRP + Visipaque320® (p = 0.470). Finally, there was no significant difference in P-selectin expression between the PRP + Visipaque270® and PRP + Iopamiron200® mixtures (p = 0.500).

CONCLUSION: At early delays of incubation, Visipaque® and Iopamiron®, which are two widely used ICA for intra-articular infiltrations, did not influence the in vitro platelet function nor the quality of PRP.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app