Impact of transvenous cardiac implantable electronic devices in chronic hemodialysis patients: a single-center, observational comparative study.

BMC Nephrology 2018 October 21
BACKGROUND: We investigated the impact of a transvenous cardiac implantable electronic device (CIED) placement on outcomes and arteriovenous vascular access (VA) patency among chronic hemodialysis patients.

METHODS: This is a single-center, observational comparative study between chronic hemodialysis patients with ipsilateral and contralateral CIED and VA. Forty-two consecutive patients who underwent both CIED placement and upper-extremity VA for hemodialysis, regardless of the sequence and time interval between these 2 procedures, were identified between January 2001 and December 2017. Patients with ipsilateral (n = 22, 52%, the ipsilateral group) and contralateral (n = 20, 48%, the contralateral group) CIED and VA were compared retrospectively; the primary outcome was any-cause mortality and cardiac mortality or the composite of any systemic complications, defined as central venous stenosis or occlusion, any device infections or tricuspid regurgitation; the secondary outcome was CIED or VA malfunction.

RESULTS: During the median follow-up period of 101 months, primary outcome incidence was significantly higher in the ipsilateral group than the contralateral group (73% vs 40%, P = 0.03), although the incidences of any-cause mortality (P = 0.28) and cardiac mortality (P > 0.99) were similar between the groups. Secondary outcome incidence did not differ significantly between the 2 groups (55% vs 30%, P = 0.36). Kaplan-Meier survival analysis revealed similar primary and secondary VA patency rates in both groups. On subgroup analysis, patients with upper arm VA had similar primary and secondary patency to those with forearm VA.

CONCLUSIONS: Despite some notable limitations of the study, the retrospective study design and small sample size, we found that the any-cause mortality incidence and VA patency did not differ between the 2 groups, but primary outcome incidence was significantly higher among patients with ipsilateral CIED and VA.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app