We have located links that may give you full text access.
Calibration Software for Quantitative PET/CT Imaging Using Pocket Phantoms.
Tomography : a Journal for Imaging Research 2018 September
Multicenter clinical trials that use positron emission tomography (PET) imaging frequently rely on stable bias in imaging biomarkers to assess drug effectiveness. Many well-documented factors cause variability in PET intensity values. Two of the largest scanner-dependent errors are scanner calibration and reconstructed image resolution variations. For clinical trials, an increase in measurement error significantly increases the number of patient scans needed. We aim to provide a robust quality assurance system using portable PET/computed tomography "pocket" phantoms and automated image analysis algorithms with the goal of reducing PET measurement variability. A set of the "pocket" phantoms was scanned with patients, affixed to the underside of a patient bed. Our software analyzed the obtained images and estimated the image parameters. The analysis consisted of 2 steps, automated phantom detection and estimation of PET image resolution and global bias. Performance of the algorithm was tested under variations in image bias, resolution, noise, and errors in the expected sphere size. A web-based application was implemented to deploy the image analysis pipeline in a cloud-based infrastructure to support multicenter data acquisition, under Software-as-a-Service (SaaS) model. The automated detection algorithm localized the phantom reliably. Simulation results showed stable behavior when image properties and input parameters were varied. The PET "pocket" phantom has the potential to reduce and/or check for standardized uptake value measurement errors.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app