Add like
Add dislike
Add to saved papers

Accuracy and Trending Ability of the Fourth-Generation FloTrac/EV1000 System in Patients With Severe Aortic Valve Stenosis Before and After Surgical Valve Replacement.

OBJECTIVE: Evaluate the accuracy and trending ability of the fourth-generation FloTrac/EV1000 (Edwards Lifesciences, Irvine, CA) system in patients with severe aortic valve stenosis by comparing FloTrac/EV1000-derived cardiac output (CCO-FT) with continuous thermodilution pulmonary artery catheter (CCO-PAC) measurements before and after surgical valve replacement.

DESIGN: Prospective clinical study.

SETTING: Anesthesia for cardiac surgery, operating room, single-center university hospital.

PARTICIPANTS: Twenty-five patients were included. After exclusion, 20 patients undergoing elective aortic valve replacement were analyzed.

INTERVENTIONS: After induction of general anesthesia, CCO-FT and CCO-PAC values were recorded every 30 seconds before and after aortic valve replacement with a bioprosthesis under cardiopulmonary bypass (CPB).

MEASUREMENTS AND MAIN RESULTS: Data were analyzed separately from skin incision to last suture and before and after CPB. Regression analyses, Bland-Altman analyses, and trending analyses (4-quadrant plot, polar plot) were performed. The percentage errors of the FloTrac/EV1000 were 69.7% and 59.3% before and after CPB, respectively. The concordance rates (CRs) and angular CRs of the FloTrac/EV1000 were 50.9% and 57.1%, and 48.7% and 61.9% before and after CPB, respectively.

CONCLUSION: This study revealed a low level of agreement and poor trending ability of the FloTrac/EV1000 system compared to continuous thermodilution pulmonary artery catheter in patients with severe aortic stenosis. Although there was a slight improvement after surgical valve replacement and CPB, the results were not within acceptable limits to replace CCO-PAC in this patient population.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app