Outcomes of distal femur fractures treated with the Synthes 4.5 mm VA-LCP Curved Condylar Plate.
International Orthopaedics 2019 July
PURPOSE: Given the recent controversy in the literature and the alarming reports of early mechanical failure associated with the use of the Synthes 4.5 mm VA-LCP Curved Condylar Plate in acute distal femur fractures, the goal of our study was to examine the outcomes and mechanical failure rates of this implant in a larger patient population.
METHODS: Patients 18 years of age and older who underwent plate fixation of their acute distal femoral fracture using the Synthes 4.5 mm VA-LCP Curved Condylar Plate were included in this retrospective study. The study data was collected through a retrospective chart review and review of the existing radiographic studies. Primary outcome measure was mechanical hardware failure while secondary outcome measures included nonunion, malunion, and medical and surgical complications.
RESULTS: A total of 74 patients (77 fractures) were included in this study. The fractures were classified according to the OTA/AO classification as 33-A2 (n = 6), 33-A3 (n = 19), 33-C1 (n = 5), 33-C2 (n = 25), and 33-C3 (n = 22). Thirty-two out of 77 fractures presented as open fractures (41.6%). A mechanical failure was observed in 7 patients (9.1%). Twenty additional patients needed a re-operation of the surgical site including two nonunion repairs, one malunion repair, 15 staged treatments of traumatic segmental bone defects, and two soft tissue debridements.
CONCLUSIONS: In our experience, the Synthes 4.5 mm VA-LCP Curved Condylar Plate is a safe and effective implant with a relatively low mechanical failure rate.
METHODS: Patients 18 years of age and older who underwent plate fixation of their acute distal femoral fracture using the Synthes 4.5 mm VA-LCP Curved Condylar Plate were included in this retrospective study. The study data was collected through a retrospective chart review and review of the existing radiographic studies. Primary outcome measure was mechanical hardware failure while secondary outcome measures included nonunion, malunion, and medical and surgical complications.
RESULTS: A total of 74 patients (77 fractures) were included in this study. The fractures were classified according to the OTA/AO classification as 33-A2 (n = 6), 33-A3 (n = 19), 33-C1 (n = 5), 33-C2 (n = 25), and 33-C3 (n = 22). Thirty-two out of 77 fractures presented as open fractures (41.6%). A mechanical failure was observed in 7 patients (9.1%). Twenty additional patients needed a re-operation of the surgical site including two nonunion repairs, one malunion repair, 15 staged treatments of traumatic segmental bone defects, and two soft tissue debridements.
CONCLUSIONS: In our experience, the Synthes 4.5 mm VA-LCP Curved Condylar Plate is a safe and effective implant with a relatively low mechanical failure rate.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app