We have located links that may give you full text access.
Evaluation Study
Journal Article
Lateral Subcutaneous Locking Compression Plate and Small Incision Reduction for Distal-third Diaphyseal Humerus Fractures.
Orthopaedic Surgery 2018 August
OBJECTIVE: Iatrogenic radial nerve injury is a great challenge for orthopaedic surgeons who deal with distal-third diaphyseal humerus fractures. Conventional open reduction and internal fixation (ORIF) remains the gold standard, but complications such as nonunion and iatrogenic radial nerve injury still occur. We fixed the fractures with a lateral locking compression plate (LCP) subcutaneously after small incision reduction to protect the radial nerve. This study reports the clinical and radiographic outcomes of our modified method.
METHODS: Thirty-eight patients with distal-third diaphyseal humerus fractures were treated with lateral subcutaneous LCP and small incision reduction at our department between September 2013 and August 2016. There were 33 males and 5 females, with an average age of 30.3 years (range, 17 to 49 years). All the cases were types A or B (AO/OTA classification, type A, 24 cases; type B, 14 cases). Among them, 6 cases were combined with preoperative radial nerve palsy. All patients were diagnosed with closed humeral fractures after X-ray examination, and had typical upper limb pain, swelling, and movement disorders. The operations were performed by a single surgeons' team. Union time, range of motion (ROM), University of California, Los Angeles (UCLA) shoulder rating scale, and Mayo Elbow Performance Index (MEPI) scores were assessed to evaluate the postoperative results.
RESULTS: All patients were followed up for an average of 11.4 months (range, 3 to 36 months). The average operation time was 75.5 min (range, 60 to 150 min) and average intraoperative radiation exposure was 10.5 s (range, 8 to 18 s). Bony union was achieved in all cases after an average of 16.2 weeks (range, 12 to 25 weeks). No complications such as infection or screw and plate fracture occurred, and no iatrogenic radial nerve injury was observed. According to the UCLA shoulder rating scale, the average score was 33.7 (range, 31 to 35), with 33 excellent (86.8%) and 5 good cases (13.2%). They were all excellent according to their MEPI scores (ranging, 94 to 100, with an average of 97.4). The average operation time for secondary removal of the plate was 15.2 min (range, 10 to 20 min), and no complications such as infection or secondary radial nerve injury occurred.
CONCLUSIONS: Lateral subcutaneous LCP and small incision reduction may reduce the risk of iatrogenic radial nerve injury significantly in the treatment of distal-third diaphyseal humerus fractures. It also leads to solid fixation, good postoperative function, and convenient removal of the plate without injuring the radial nerve.
METHODS: Thirty-eight patients with distal-third diaphyseal humerus fractures were treated with lateral subcutaneous LCP and small incision reduction at our department between September 2013 and August 2016. There were 33 males and 5 females, with an average age of 30.3 years (range, 17 to 49 years). All the cases were types A or B (AO/OTA classification, type A, 24 cases; type B, 14 cases). Among them, 6 cases were combined with preoperative radial nerve palsy. All patients were diagnosed with closed humeral fractures after X-ray examination, and had typical upper limb pain, swelling, and movement disorders. The operations were performed by a single surgeons' team. Union time, range of motion (ROM), University of California, Los Angeles (UCLA) shoulder rating scale, and Mayo Elbow Performance Index (MEPI) scores were assessed to evaluate the postoperative results.
RESULTS: All patients were followed up for an average of 11.4 months (range, 3 to 36 months). The average operation time was 75.5 min (range, 60 to 150 min) and average intraoperative radiation exposure was 10.5 s (range, 8 to 18 s). Bony union was achieved in all cases after an average of 16.2 weeks (range, 12 to 25 weeks). No complications such as infection or screw and plate fracture occurred, and no iatrogenic radial nerve injury was observed. According to the UCLA shoulder rating scale, the average score was 33.7 (range, 31 to 35), with 33 excellent (86.8%) and 5 good cases (13.2%). They were all excellent according to their MEPI scores (ranging, 94 to 100, with an average of 97.4). The average operation time for secondary removal of the plate was 15.2 min (range, 10 to 20 min), and no complications such as infection or secondary radial nerve injury occurred.
CONCLUSIONS: Lateral subcutaneous LCP and small incision reduction may reduce the risk of iatrogenic radial nerve injury significantly in the treatment of distal-third diaphyseal humerus fractures. It also leads to solid fixation, good postoperative function, and convenient removal of the plate without injuring the radial nerve.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app