We have located links that may give you full text access.
Decreasing subthalamic deep brain stimulation frequency reverses cognitive interference during gait initiation in Parkinson's disease.
Clinical Neurophysiology : Official Journal of the International Federation of Clinical Neurophysiology 2018 November
OBJECTIVE: Freezing of gait (FOG) represents a major burden for Parkinson's disease (PD) patients. High-frequency (130-Hz) subthalamic deep-brain-stimulation (STN-DBS) has been reported to aggravate FOG whereas lowering the frequency to 60-80 Hz improves FOG. To further understand the effects of STN-DBS on FOG, we assessed the effects of 80-Hz and 130-Hz STN-DBS on gait initiation performance, in relation to motor and executive function processing.
METHODS: Gait initiation was recorded in 19 PD patients and 20 controls, combined or not with a cognitive interference task with a modified Stroop paradigm. PD patients were recorded before surgery with and without dopaminergic treatment, and after surgery with 80-Hz and 130-Hz STN-DBS in a randomised double-blind crossover study.
RESULTS: In the absence of cognitive interference, PD patients exhibited significant gait initiation improvement with dopaminergic treatment, 80-Hz and 130-Hz STN-DBS. Nine patients performed the cognitive interference task. With 130-Hz STN-DBS, all gait initiation parameters were significantly degraded, whereas the cognitive interference task induced no major changes before surgery and with 80-Hz STN-DBS, as in controls.
CONCLUSIONS: High-frequency STN-DBS leads to an inability to simultaneously process motor and cognitive information while this ability seems preserved with low-frequency STN-DBS.
SIGNIFICANCE: This study supports the potential benefit of 80-Hz STN-DBS on FOG.
METHODS: Gait initiation was recorded in 19 PD patients and 20 controls, combined or not with a cognitive interference task with a modified Stroop paradigm. PD patients were recorded before surgery with and without dopaminergic treatment, and after surgery with 80-Hz and 130-Hz STN-DBS in a randomised double-blind crossover study.
RESULTS: In the absence of cognitive interference, PD patients exhibited significant gait initiation improvement with dopaminergic treatment, 80-Hz and 130-Hz STN-DBS. Nine patients performed the cognitive interference task. With 130-Hz STN-DBS, all gait initiation parameters were significantly degraded, whereas the cognitive interference task induced no major changes before surgery and with 80-Hz STN-DBS, as in controls.
CONCLUSIONS: High-frequency STN-DBS leads to an inability to simultaneously process motor and cognitive information while this ability seems preserved with low-frequency STN-DBS.
SIGNIFICANCE: This study supports the potential benefit of 80-Hz STN-DBS on FOG.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app