Intraocular lens power calculation in eyes with previous corneal refractive surgery.
BACKGROUND: This review aims to explain the reasons why intraocular lens (IOL) power calculation is challenging in eyes with previous corneal refractive surgery and what solutions are currently available to obtain more accurate results.
REVIEW: After IOL implantation in eyes with previous LASIK, PRK or RK, a refractive surprise can occur because i) the altered ratio between the anterior and posterior corneal surface makes the keratometric index invalid; ii) the corneal curvature radius is measured out of the optical zone; and iii) the effective lens position is erroneously predicted if such a prediction is based on the post-refractive surgery corneal curvature. Different methods are currently available to obtain the best refractive outcomes in these eyes, even when the perioperative data (i.e. preoperative corneal power and surgically induced refractive change) are not known. In this review, we describe the most accurate methods based on our clinical studies.
CONCLUSIONS: IOL power calculation after myopic corneal refractive surgery can be calculated with a variety of methods that lead to relatively accurate outcomes, with 60 to 70% of eyes showing a prediction error within 0.50 diopters.
REVIEW: After IOL implantation in eyes with previous LASIK, PRK or RK, a refractive surprise can occur because i) the altered ratio between the anterior and posterior corneal surface makes the keratometric index invalid; ii) the corneal curvature radius is measured out of the optical zone; and iii) the effective lens position is erroneously predicted if such a prediction is based on the post-refractive surgery corneal curvature. Different methods are currently available to obtain the best refractive outcomes in these eyes, even when the perioperative data (i.e. preoperative corneal power and surgically induced refractive change) are not known. In this review, we describe the most accurate methods based on our clinical studies.
CONCLUSIONS: IOL power calculation after myopic corneal refractive surgery can be calculated with a variety of methods that lead to relatively accurate outcomes, with 60 to 70% of eyes showing a prediction error within 0.50 diopters.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app