We have located links that may give you full text access.
Determination of four main components of gentamicin in animal tissues after solid-phase extraction by high-performance liquid chromatography/tandem mass spectrometry.
Rapid Communications in Mass Spectrometry : RCM 2018 October 31
RATIONALE: An analytical method for gentamicin in animal tissues was developed and validated. An alkaline mobile phase with an HPH C8 column was selected so that all the four gentamicin components were retained and eluted without using fluorinated ion-pairing reagents.
METHODS: The method is sufficiently sensitive and highly selective, using a strong cation-exchange solid-phase extraction cartridge (PCX) to clean up the samples. Different types of solid-phase extraction columns and membranes were considered to obtain a high recovery. The method was validated on spiking samples, recovery, inter- and intra-assay variation, to ensure its accuracy and precision.
RESULTS: The LOQ (S/N ≥ 10) for gentamicin in goat meat, liver, kidney and adipose tissue was 25, 50, 30 and 30 ng/g, respectively; the LOD (S/N ≥ 3) was 5, 10, 10 and 10 ng/g, respectively. The recoveries were between 88% and 106%. The method in all animal tissues was calibrated from 10 to 1000 μg/L in the matrix-assisted standard solution.
CONCLUSIONS: The novelty of this method is that the commonly used fluorinated ion-pairing reagent was not used in the mobile phase in our analysis, greatly reducing the contamination of the ESI source in negative mode. Moreover, the four gentamicin components were clearly separated via chromatographic separation.
METHODS: The method is sufficiently sensitive and highly selective, using a strong cation-exchange solid-phase extraction cartridge (PCX) to clean up the samples. Different types of solid-phase extraction columns and membranes were considered to obtain a high recovery. The method was validated on spiking samples, recovery, inter- and intra-assay variation, to ensure its accuracy and precision.
RESULTS: The LOQ (S/N ≥ 10) for gentamicin in goat meat, liver, kidney and adipose tissue was 25, 50, 30 and 30 ng/g, respectively; the LOD (S/N ≥ 3) was 5, 10, 10 and 10 ng/g, respectively. The recoveries were between 88% and 106%. The method in all animal tissues was calibrated from 10 to 1000 μg/L in the matrix-assisted standard solution.
CONCLUSIONS: The novelty of this method is that the commonly used fluorinated ion-pairing reagent was not used in the mobile phase in our analysis, greatly reducing the contamination of the ESI source in negative mode. Moreover, the four gentamicin components were clearly separated via chromatographic separation.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app