Objective: Delineation of treatment volumes is a major source of uncertainties in radiotherapy (RT). This is also true for rectal cancer patients undergoing neoadjuvant RT, with a potential impact on treatment quality. We investigated the role of the digital platform Anatom-e (Anatom-e Information Sytems Ltd., Houston, Texas) in increasing the compliance to follow a specific treatment protocol in a multicentric setting.

Materials and methods: Two clinical cases of locally advanced rectal cancer were chosen. Participants were instructed to follow the 2009 Radiation Therapy Oncology Group consensus atlas and asked to manually segment clinical target volumes (CTVs), for both patient 1 and 2, on day 1 with and without the use of Anatom-e. After one week (day 2), the same radiation oncologist contoured again, with and without Anatom-e, the same CT series. Intraobserver (Intra-OV) and interobserver (Inter-OV) variability were evaluated with the Dice similarity coefficient (DSC), the Hausdorff distance (HD) and mean distance to agreement (MDA).

Results: For clinical case 1, no significant difference was found for Intra-OV and Inter-OV. For clinical case 2, no significant difference was found for Intra-OV but a statistically significant difference was found for Inter-OV in DSC when using or not the platform. Mean DCS was 0.65 (SD: ±0.64; range: 0.58-0.79) for day 1 vs reference volume without Anatom-e and 0.72 (SD: ±0.39; range: 0.67-0.77) (p = 0.03) with it. Mean MDA was lower with Anatom-e (3.61; SD: ±1.33; range: 2.85-4.78) than without (4.14; SD: ±2.97; range: 2.18-5.21), with no statistical significance (p = 0.21) The use of Anatom-e decreased the SD from 2.97 to 1.33. Mean HD was lower with Anatom-e (26.06; SD: ±2.05; range: 24.08-32.62), with no statistical significance (p = 0.14) compared to that without (31.39; SD: ±1.31; range: 26.14-48.72).

Conclusions: The use of Anatom-e decreased the Inter-OV in the CTV delineation process for locally advanced rectal cancer with complex disease presentation planned for neoadjuvant RT. This system may be potentially helpful in increasing the compliance to follow shared guidelines and protocols.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app