We have located links that may give you full text access.
COMPARATIVE STUDY
JOURNAL ARTICLE
OBSERVATIONAL STUDY
Comparison of three non-invasive hemodynamic monitoring methods in critically ill children.
PloS One 2018
INTRODUCTION: Hemodynamic parameters measurements were widely conducted using pulmonary artery catheter (PAC) with thermodilution as a reference standard. Due to its technical difficulties in children, transthoracic echocardiography (TTE) has been widely employed instead. Nonetheless, TTE requires expertise and is time-consuming. Noninvasive cardiac output monitoring such as ultrasonic cardiac output monitor (USCOM) and electrical velocimetry (EV) can be performed rapidly with less expertise requirement. Presently, there are inconsistent evidences, variable precision, and reproducibility of EV, USCOM and TTE measurements. Our objective was to compare USCOM, EV and TTE in hemodynamic measurements in critically ill children.
MATERIALS AND METHODS: This was a single center, prospective observational study in critically ill children. Children with congenital heart diseases and unstable hemodynamics were excluded. Simultaneous measurements of hemodynamic parameters were conducted using USCOM, EV, and TTE. Inter-rater reliability was determined. Bland-Altman plots were used to analyse agreement of assessed parameters.
RESULTS: Analysis was performed in 121 patients with mean age of 4.9 years old and 56.2% of male population. Interrater reliability showed acceptable agreement in all measured parameters (stroke volume (SV), cardiac output (CO), velocity time integral (VTI), inotropy (INO), flow time corrected (FTC), aortic valve diameter (AV), systemic vascular resistance (SVR), and stroke volume variation (SVV); (Cronbach's alpha 0.76-0.98). Percentages of error in all parameters were acceptable by Bland-Altman analysis (9.2-28.8%) except SVR (30.8%) and SVV (257.1%).
CONCLUSION: Three noninvasive methods might be used interchangeably in pediatric critical care settings with stable hemodynamics. Interpretation of SVV and SVR measurements must be done with prudence.
MATERIALS AND METHODS: This was a single center, prospective observational study in critically ill children. Children with congenital heart diseases and unstable hemodynamics were excluded. Simultaneous measurements of hemodynamic parameters were conducted using USCOM, EV, and TTE. Inter-rater reliability was determined. Bland-Altman plots were used to analyse agreement of assessed parameters.
RESULTS: Analysis was performed in 121 patients with mean age of 4.9 years old and 56.2% of male population. Interrater reliability showed acceptable agreement in all measured parameters (stroke volume (SV), cardiac output (CO), velocity time integral (VTI), inotropy (INO), flow time corrected (FTC), aortic valve diameter (AV), systemic vascular resistance (SVR), and stroke volume variation (SVV); (Cronbach's alpha 0.76-0.98). Percentages of error in all parameters were acceptable by Bland-Altman analysis (9.2-28.8%) except SVR (30.8%) and SVV (257.1%).
CONCLUSION: Three noninvasive methods might be used interchangeably in pediatric critical care settings with stable hemodynamics. Interpretation of SVV and SVR measurements must be done with prudence.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app