We have located links that may give you full text access.
[Evaluation in 18 hours of Cardiac Dynamics with the Mathematical Law of Dynamic Systems]
Revista de la Facultad de Ciencias Médicas 2017 December 22
Introduction: an exponential law has been found for chaotic dynamic cardiac systems, making it possible to quantify the differences between normal and pathological cardiac dynamics.
Methodology: 120 electrocardiographic records were analyzed, 40 corresponded to subjects within the limits of normality and 80 with different pathologies. For each holter the attractors generated with the data during 18 hours and throughout the dynamics were analyzed. The fractal dimension of the attractor and its spatial occupation were calculated. To these measures was applied the diagnosis mathematical evaluation previously developed, comparing the evaluation for 18 hours and for the whole registry; sensitivity, specificity and Kappa coefficient were finally calculated.
Results: For the normal dynamics, the occupancy spaces in the Kp grid were between 200 and 381 for the evaluation of the whole holter, and between 201 and 384 in the evaluation during 18 hours, showing the closeness in the measurements, which allows that the decrease in the time of the evaluation is consistent, this same proximity was observed for the diseased and acute dynamics.
Conclusion: It was evidenced the clinical applicability in 18 hours of the exponential law in the chaotic cardiac dynamics associated with arrhythmias showing to be useful for the prediction of the evolution towards acute states of the dynamics
Methodology: 120 electrocardiographic records were analyzed, 40 corresponded to subjects within the limits of normality and 80 with different pathologies. For each holter the attractors generated with the data during 18 hours and throughout the dynamics were analyzed. The fractal dimension of the attractor and its spatial occupation were calculated. To these measures was applied the diagnosis mathematical evaluation previously developed, comparing the evaluation for 18 hours and for the whole registry; sensitivity, specificity and Kappa coefficient were finally calculated.
Results: For the normal dynamics, the occupancy spaces in the Kp grid were between 200 and 381 for the evaluation of the whole holter, and between 201 and 384 in the evaluation during 18 hours, showing the closeness in the measurements, which allows that the decrease in the time of the evaluation is consistent, this same proximity was observed for the diseased and acute dynamics.
Conclusion: It was evidenced the clinical applicability in 18 hours of the exponential law in the chaotic cardiac dynamics associated with arrhythmias showing to be useful for the prediction of the evolution towards acute states of the dynamics
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app