We have located links that may give you full text access.
The third ventricle of the human fetal brain: Normative data and pathologic correlation. A 3D transvaginal neurosonography study.
Prenatal Diagnosis 2018 August
OBJECTIVE: The objective of the study are to describe (a) the technical aspects and (b) the anatomical boundaries of the fetal third ventricle (3V) on the midsagittal sonographic view and to assess (c) different biometric parameters in normal and abnormal fetuses and (d) and their reproducibility.
METHODS: This study included 67 normal and 50 CNS anomalies fetuses which include (1) obstructive severe ventriculomegaly (SVM; atrial width ≥ 15 mm), (2) moderate ventriculomegaly (10-14.9 mm), and (3) corpus callosum agenesis (ACC). All underwent transvaginal 3D neurosonography of the midsagittal view of the 3V. The following parameters were measured: area, perimeter, craniocaudal and anteroposterior (AP) diameters, interthalamic adhesion diameter (ITAD), wedge angle, and the ratio between the last 2 variables (ITAD/WA). Repeatability was also assessed.
RESULTS: The ITAD and the ITAD/WA are significantly different between normal fetuses and the SVM (P ≤ .001). Interthalamic adhesion diameter of ≤7.1 mm is able to identify SVM with 98.6% accuracy (CI: 0.92-0.99). In ACC cases, the AP diameter is significantly shorter than both normal fetuses and ventriculomegaly. Intraobserver/interobserver reliability was good for most variables.
CONCLUSIONS: Transvaginal neurosonography enables visualization of the normal and abnormal fetal third ventricle. An ITAD <7.1 identifies aqueductal stenosis as the likely etiology of severe ventriculomegaly with an accuracy of 98.6%.
METHODS: This study included 67 normal and 50 CNS anomalies fetuses which include (1) obstructive severe ventriculomegaly (SVM; atrial width ≥ 15 mm), (2) moderate ventriculomegaly (10-14.9 mm), and (3) corpus callosum agenesis (ACC). All underwent transvaginal 3D neurosonography of the midsagittal view of the 3V. The following parameters were measured: area, perimeter, craniocaudal and anteroposterior (AP) diameters, interthalamic adhesion diameter (ITAD), wedge angle, and the ratio between the last 2 variables (ITAD/WA). Repeatability was also assessed.
RESULTS: The ITAD and the ITAD/WA are significantly different between normal fetuses and the SVM (P ≤ .001). Interthalamic adhesion diameter of ≤7.1 mm is able to identify SVM with 98.6% accuracy (CI: 0.92-0.99). In ACC cases, the AP diameter is significantly shorter than both normal fetuses and ventriculomegaly. Intraobserver/interobserver reliability was good for most variables.
CONCLUSIONS: Transvaginal neurosonography enables visualization of the normal and abnormal fetal third ventricle. An ITAD <7.1 identifies aqueductal stenosis as the likely etiology of severe ventriculomegaly with an accuracy of 98.6%.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app