PURPOSE: Magnetic resonance venography (MRV) has not been validated in pre-operative planning of the dural venous sinus stenting (VSS) among idiopathic intracranial hypertension (IIH) patients. We aim to prospectively evaluate dural venous sinus measurement in IIH patient population on two-dimensional time-of-flight (2D-TOF) MRV and Three-dimensional contrast-enhanced (3D-CE) MRV acquisitions and compare them against real-time endoluminal measurements with intravascular ultrasound (IVUS), served as the reference.

MATERIALS AND METHODS: The study has been approved by the Weill Cornell Medicine institutional review board. All patients signed written informed consent approved by IRB. Prospective evaluation of forty-five consecutive IIH patients treated with VSS at our institution were evaluated. Patients with pre-stent magnetic resonance venography (MRV) ≤ 6-months of VSS and intravascular ultrasound (IVUS) during VSS constituted the study population. Maximum diameter (in mm), Area (in cm2) and Perimeter (in cm) were measured at posterior 1/3rd of superior sagittal sinus (SSS), proximal transverse sinus (PTS), proximal sigmoid sinus (PSS) and mid sigmoid sinus (MSS) on 2D-TOF-MRV, 3D-CE-MRV and IVUS. Statistical analysis performed using box and whisker plots, Bland-Altman analysis and paired sample t-test.

RESULTS: Twenty (n = 20) patients constituted our study population. The mean age was 30±11 years (7-59 years) and 18 out of 20 were female patients. Mean weight and BMI (range) were 86.3±18.3 kilograms (30.8-107.5 kgs) and 32.9±6.8 kg/M2 (16.4-48.3kg/M2) respectively. The CE-MRV significantly oversized the cerebral venous sinuses compared to TOF-MRV (Dmax: +2.0±1.35 mm, p<0.001; Area: +13.31±10.92 mm2, p<0.001 and Perimeter: +4.79±3.4 mm, p<0.001) and IVUS (Dmax: +1.52±2.16 mm, p<0.001; Area: +10.03±21.5 mm2, p<0.001 and Perimeter: +4.15±3.27 mm, p<0.001). The TOF-MRV sinus measurements were in good agreement with the IVUS measurements with no significant variation (Dmax: +.21±2.23 mm, p = 0.49; Area: +2.51±20.41mm2, p = 0.347 and Perimeter: +.001±1.11 mm, p = 0.991).

CONCLUSION: We report baseline cerebral venous sinus measurements (maximum diameter, area and perimeter) in patients with idiopathic intracranial hypertension. In our experience, TOF-MRV is a reliable representation of endoluminal cerebral venous sinus dimensions, and CE-MRV measurements reflected an overestimation of the endoluminal sinus dimensions when compared against the real time IVUS measurements.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
29856739
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"