Validation of the BetaStar ® Advanced for Tetracyclines Test Kit for the Screening of Bulk Tank and Tanker Truck Milks for the Presence of Tetracycline Drug Residues

David Ankrapp, Benjamin Schaus, Lauren Clements, Frank Klein, Jennifer Rice, John Rejman, Joe Boison, Philip Kijak, Weilin Shelver
Journal of AOAC International 2018 November 1, 101 (6): 1794-1805
29743134
A validation study was conducted for an immunochromatographic method (BetaStar® Advanced for Tetracyclines) for detection of tetracycline antibiotic residues in raw, commingled bovine milk. The assay was demonstrated to detect tetracycline, chlortetracycline, and oxytetracycline at levels below the FDA tolerance levels but above the maximum sensitivity thresholds established by the National Conference on Interstate Milk Shipments. Results of internal and independent laboratory dose-response studies employing spiked samples were in agreement. All three drugs at the approximate 90/95% sensitivity levels were detected in milk collected from cows that had been treated with the specific drug. Selectivity of the assay was 100%, as no false-positive results were obtained in testing 881 control milk samples. Testing the estimated 90/95 sensitivity level for tetracycline (213 ppb), chlortetracycline (272 ppb), and oxytetracycline (180 ppb) and at 1000 ppb for each antibiotic resulted in 100% positive tests for each tetracycline. Results of ruggedness experiments established the operating parameter tolerances for the test. Results of cross-reactivity testing established that the assay detects certain other tetracycline drugs but does not cross-react with any of 32 drugs belonging to seven different drug classes. Abnormally high bacterial or somatic cell counts (SCC) in raw milk produced no assay interference.

Full Text Links

Find Full Text Links for this Article

Discussion

You are not logged in. Sign Up or Log In to join the discussion.

Related Papers

Remove bar
Read by QxMD icon Read
29743134
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"