We have located links that may give you full text access.
New insertion support device assisted the accurate placement of tunneled cuffed catheter: First experience of 10 cases.
Journal of Vascular Access 2018 September
INTRODUCTION: The tunneled cuffed catheter is used in hemodialysis patients for whom an arteriovenous fistula or arteriovenous graft is not suitable or for bridging usage of them. Accurate placement of a tunneled cuffed catheter is necessary for safe hemodialysis, but placement is sometimes difficult because of individual body differences. We developed a new device to support accurate placement of the tunneled cuffed catheter. In this study, we report our first clinical experience of the device.
METHODS: We made the device by expanded polytetrafluoroethylene with some special processes. The processes enable it to maintain plasticity and temporary shape in the autoclaved condition. The device is laid on the surface of the patient's body to mark the root of the catheter with a felt-tipped marker before catheterization. That enables us to know the accurate catheter root and tunneled cuffed catheter exit site on the body surface. Ten patients underwent tunneled cuffed catheter insertion according to the marking.
CASE DESCRIPTION: The mean age was 71.3 ± 12.8 years. The tunneled cuffed catheter was safely placed according to the marking in all patients, and all catheter tips were placed in the right atrium. The mean verification tip location difference before and after catheterization was 0.70 ± 0.48 cm. This result indicated that the device could assist in inserting a catheter accurately within an error of 1.18 cm. The tunneled cuffed catheters were patent in all the cases, without replacement and complications until the end of bridging use or during the observation period.
CONCLUSION: Our newly developed insertion support device enhances safety and prevents catheter waste during replacement.
METHODS: We made the device by expanded polytetrafluoroethylene with some special processes. The processes enable it to maintain plasticity and temporary shape in the autoclaved condition. The device is laid on the surface of the patient's body to mark the root of the catheter with a felt-tipped marker before catheterization. That enables us to know the accurate catheter root and tunneled cuffed catheter exit site on the body surface. Ten patients underwent tunneled cuffed catheter insertion according to the marking.
CASE DESCRIPTION: The mean age was 71.3 ± 12.8 years. The tunneled cuffed catheter was safely placed according to the marking in all patients, and all catheter tips were placed in the right atrium. The mean verification tip location difference before and after catheterization was 0.70 ± 0.48 cm. This result indicated that the device could assist in inserting a catheter accurately within an error of 1.18 cm. The tunneled cuffed catheters were patent in all the cases, without replacement and complications until the end of bridging use or during the observation period.
CONCLUSION: Our newly developed insertion support device enhances safety and prevents catheter waste during replacement.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.