Permanent-temporary pacemakers in the management of patients with conduction abnormalities after transcatheter aortic valve replacement.
BACKGROUND: Damage to the cardiac conduction system requiring permanent pacemaker (PPM) implantation is a known adverse outcome of transcatheter aortic valve replacement (TAVR). A permanent-temporary pacemaker (PTPM) is a device that involves an active-fixation lead attached to an external pulse generator taped to the skin. We reviewed the utility of PTPMs as a temporary bridge measure after TAVR in patients with conduction abnormalities that do not meet conventional criteria for PPM placement.
METHODS: Between January 01, 2013 and December 31, 2015, we analyzed 67 patients who received PTPM after TAVR. Baseline demographics, comorbidities, type and size of the valve, pre-TAVR electrocardiograms (ECGs), post-TAVR ECGs at 1 day, 1 month, and 6 months, and pacemaker interrogation results were reviewed for each patient if available.
RESULTS: The mean age of patients was 80.5 ± 9.1 years. PTPM were placed for 2.3 ± 2.4 days. Among these patients, 44.8% (n = 30) received a PPM prior to discharge. Male gender (OR 2.84, 95% CI 1.05-7.69, p = 0.05) and an increase in QRS duration post-TAVR (p = 0.01) were associated with PPM placement. Pacemaker interrogation data of 11 patients with PPM revealed that 27% (n = 3) had < 1% V-pacing requirements and < 10% A-pacing requirements.
CONCLUSIONS: In post-TAVR patients who develop conduction abnormalities that do not meet conventional PPM implantation indications, PTPM safely provides a time period for further assessment and may prevent unnecessary PPM implantation. Male gender and an increase in QRS duration post-TAVR are associated with PPM implantation. Additionally, some patients may recover from their conduction disturbances and demonstrate low pacemaker utilization.
METHODS: Between January 01, 2013 and December 31, 2015, we analyzed 67 patients who received PTPM after TAVR. Baseline demographics, comorbidities, type and size of the valve, pre-TAVR electrocardiograms (ECGs), post-TAVR ECGs at 1 day, 1 month, and 6 months, and pacemaker interrogation results were reviewed for each patient if available.
RESULTS: The mean age of patients was 80.5 ± 9.1 years. PTPM were placed for 2.3 ± 2.4 days. Among these patients, 44.8% (n = 30) received a PPM prior to discharge. Male gender (OR 2.84, 95% CI 1.05-7.69, p = 0.05) and an increase in QRS duration post-TAVR (p = 0.01) were associated with PPM placement. Pacemaker interrogation data of 11 patients with PPM revealed that 27% (n = 3) had < 1% V-pacing requirements and < 10% A-pacing requirements.
CONCLUSIONS: In post-TAVR patients who develop conduction abnormalities that do not meet conventional PPM implantation indications, PTPM safely provides a time period for further assessment and may prevent unnecessary PPM implantation. Male gender and an increase in QRS duration post-TAVR are associated with PPM implantation. Additionally, some patients may recover from their conduction disturbances and demonstrate low pacemaker utilization.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app