Add like
Add dislike
Add to saved papers

The popliteus tendon provides a safe and reliable location for all-inside meniscal repair device placement.

PURPOSE: Repairs of the posterior horn of the lateral meniscus can be technically challenging. In contrast to medial meniscus repairs, the capsule around the posterior segment attachment of the lateral meniscus is quite thin. This study evaluates the clinical results of an arthroscopic all-inside repair technique for unstable, vertical, lateral meniscus tears, using a suture repair placed directly into the popliteus tendon.

METHODS: A retrospective analysis of prospectively collected data from the SANTI database was performed. All patients who had undergone combined ACL reconstruction with lateral meniscus all-inside repair, using sutures placed in the popliteus tendon, between 2011 and 2015, were included. Patients were reviewed clinically at 1 and 2 years' follow-up. At final follow-up, all patients were contacted to identify if they underwent further surgery or had knee pain, locking or effusion. Symptomatic patients were recalled for clinical evaluation by a physician and Magnetic Resonance Imaging of the knee. Operative notes for those undergoing further surgery were reviewed and rates and type of re-operation, including for failed lateral meniscal repair were recorded.

RESULTS: Two hundred patients (mean age 28.6 ± 10.2 years) with a mean follow-up of 45.5 ± 12.8 months (range 24.7-75.2) were included. The mean Subjective International Knee Documentation Committee (IKDC) at final follow-up was 85.0 ± 11.3. The post-operative mean side-to-side laxity measured at 1 year was 0.6 ± 1.0 mm. Twenty-six patients underwent re-operation (13%) at a mean follow-up of 14.8 ± 7.8 months. The ACL graft rupture rate was 5.0%. Other causes for re-operation included medial meniscus tear (2.5%), cyclops lesion (1.5%) and septic arthritis (0.5%). The lateral meniscus repair failure rate was 3.5%. No specific complications relating to placement of sutures in the popliteus tendon were identified.

CONCLUSION: Arthroscopic all-inside repair of unstable, vertical, lateral meniscus tears using a suture placed in the popliteus tendon is a safe technique. It is associated with a very low failure rate with no specific complications.

LEVEL OF EVIDENCE: Level IV.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app