CASE REPORTS
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Endolymphatic Thoracic Duct Stent-Graft Reconstruction for Chylothorax: Approach, Technical Success, Safety, and Short-term Outcomes.

BACKGROUND: To report approach, technical success, safety, and short-term outcomes of thoracic duct stent-graft reconstruction for the treatment of chylothorax.

METHODS: Two patients, 1 (50%) male and 1 (50%) female, with mean age of 38 years (range: 16-59 years) underwent endolymphatic thoracic duct stent-graft reconstruction between September 2016 and July 2017. Patients had radiographic left-sided chylothoraces (n = 2) from idiopathic causes (n = 1) and heart transplantation (n = 1). In both (100%) patients, antegrade lymphatic access was used to opacify the thoracic duct after which retrograde access was used for thoracic duct stent-graft placement. Pelvic lymphangiography technical success, antegrade cisterna chyli cannulation technical success, thoracic duct opacification technical success, retrograde thoracic duct access technical success, thoracic duct stent-graft reconstruction technical success, ethiodized oil volume, contrast volume, estimated blood loss, procedure time, fluoroscopy time, radiation dose, clinical success, complications, deaths, and follow-up were recorded.

RESULTS: Pelvic lymphangiography, antegrade cisterna chyli cannulation, thoracic duct opacification, retrograde thoracic duct access, and thoracic duct stent-graft reconstruction were technically successful in both (100%) patients. Mean ethiodized oil volume was 8 mL (range: 5-10 mL). Mean contrast volume was 13 mL (range: 5-20 mL). Mean estimated blood loss was 13 mL (range: 10-15 mL). Mean fluoroscopy time was 50.4 min (range: 31.2-69.7 min). Mean dose area product and reference air kerma were 954.4 μGmy2 (range: 701-1,208 μGmy2 ) and 83.5 mGy (range: 59-108 mGy), respectively. Chylothorax resolved in both (100%) patients. There were no minor or major complications directly related to the procedure.

CONCLUSIONS: Thoracic duct stent-graft reconstruction may be a technically successful and safe alternative to thoracic duct embolization, disruption, and surgical ligation for the treatment of chylothorax. Additional studies are warranted.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app