Reproducibility of diaphragm thickness measurements by ultrasonography in patients on mechanical ventilation.
World Journal of Critical Care Medicine 2017 November 5
AIM: To prospectively evaluate the reproducibility of diaphragm thickness measurement by ultrasonography at the bedside by critical care physicians in patients on invasive mechanical ventilation.
METHODS: In a prospective observational study of 64 invasively ventilated patients, diaphragmatic thickness measurement was taken by 2 different observers at the same site. Three measurements were taken by each observer and averaged. The intraobserver and interobserver variability was assessed by estimation of intraclass correlation coefficient. The limits of agreement were plotted as the difference between two observations against the average of the two observations in Bland and Altman analysis.
RESULTS: The mean diaphragm thickness at the functional residual capacity was 2.29 ± 0.4 mm and the lower limit of the normal, i.e ., the 5th percentile was 1.7 mm (95%CI: 1.6-1.8). The intraclass correlation coefficient for intraobserver variability was 0.986 (95%CI: 0.979-0.991) with a P value of < 0.001. The intraclass correlation coefficient for interobserver variability was 0.987 (95%CI: 0.949-0.997) with a P value of < 0.001. In Bland and Altman analysis, both intraobserver and interobserver measurements showed high limits of agreement.
CONCLUSION: Our study demonstrates that the measurement of diaphragm thickness by ultrasound can be accurately performed by critical care physicians with high degree of reproducibility in patients on mechanical ventilation.
METHODS: In a prospective observational study of 64 invasively ventilated patients, diaphragmatic thickness measurement was taken by 2 different observers at the same site. Three measurements were taken by each observer and averaged. The intraobserver and interobserver variability was assessed by estimation of intraclass correlation coefficient. The limits of agreement were plotted as the difference between two observations against the average of the two observations in Bland and Altman analysis.
RESULTS: The mean diaphragm thickness at the functional residual capacity was 2.29 ± 0.4 mm and the lower limit of the normal, i.e ., the 5th percentile was 1.7 mm (95%CI: 1.6-1.8). The intraclass correlation coefficient for intraobserver variability was 0.986 (95%CI: 0.979-0.991) with a P value of < 0.001. The intraclass correlation coefficient for interobserver variability was 0.987 (95%CI: 0.949-0.997) with a P value of < 0.001. In Bland and Altman analysis, both intraobserver and interobserver measurements showed high limits of agreement.
CONCLUSION: Our study demonstrates that the measurement of diaphragm thickness by ultrasound can be accurately performed by critical care physicians with high degree of reproducibility in patients on mechanical ventilation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app