Add like
Add dislike
Add to saved papers

Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.

BACKGROUND: To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery.

METHODS AND RESULTS: Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P <0.0001 for both).

CONCLUSIONS: The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app