JOURNAL ARTICLE
MULTICENTER STUDY
RESEARCH SUPPORT, N.I.H., EXTRAMURAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Resting and exercise haemodynamics in relation to six-minute walk test in patients with heart failure and preserved ejection fraction.

AIMS: Patients with heart failure and preserved ejection fraction (HFpEF) are characterized by functional impairment and an abnormal haemodynamic response to exercise. The six-minute walk test (6MWT) serves as a standardized test for functional capacity quantification in heart failure patients, and is associated with cardiovascular outcomes. However, as the association between 6MWT and haemodynamic parameters during rest and exercise in HFpEF patients is unknown, we sought to elucidate this relationship.

METHODS AND RESULTS: Overall, 64 patients enrolled in the REDUCE LAP-HF trial completed a 6MWT at baseline. Univariate and multivariable linear regression models were used to assess the associations between 6MWT and measured or derived haemodynamic variables at baseline, during light/moderate exercise (20 W), and at peak supine exercise. The average 6MWT distance was 318 ± 106 m. At rest, in a multivariable model, only pulmonary capillary wedge pressure (PCWP) was significantly associated with 6MWT [coefficient: -5.4, 95% confidence interval (CI) -10.4, -0.5, P = 0.033]. During light/moderate exercise, mean pulmonary artery pressure was associated with 6MWT in a multivariable model (coefficient: -3.5, 95% CI -6.8, -0.3, P = 0.033). During peak exercise, central venous pressure, cardiac index (CI), and PCWP/CI correlated with 6MWT; however, workload corrected PCWP was the only variable independently associated with 6MWT (coefficient: -0.8, 95% CI -1.3, -0.4, P < 0.001). The variance in 6MWT was modestly explained by measured or derived haemodynamic variables at rest or at any stage of exercise (r2  = 7-17%).

CONCLUSION: Workload corrected PCWP correlated best with 6MWT performance in HFpEF patients. Baseline haemodynamic variables were modestly correlated with 6MWT, suggesting that 6MWT performance in HFpEF patients may be significantly influenced by extra-cardiac factors.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app