BACKGROUND: Validation of administrative data case definitions is key for accurate passive surveillance of disease. Transient ischemic attack (TIA) is a condition primarily managed in the emergency department. However, prior validation studies have focused on data after inpatient hospitalization. We aimed to determine the validity of the Canadian 10th International Classification of Diseases (ICD-10-CA) codes for TIA in the national ambulatory administrative database.

METHODS: We performed a diagnostic accuracy study of four ICD-10-CA case definition algorithms for TIA in the emergency department setting. The study population was obtained from two ongoing studies on the diagnosis of TIA and minor stroke versus stroke mimic using serum biomarkers and neuroimaging. Two reference standards were used 1) the emergency department clinical diagnosis determined by chart abstractors and 2) the 90-day final diagnosis, both obtained by stroke neurologists, to calculate the sensitivity, specificity, positive and negative predictive values (PPV and NPV) of the ICD-10-CA algorithms for TIA.

RESULTS: Among 417 patients, emergency department adjudication showed 163 (39.1%) TIA, 155 (37.2%) ischemic strokes, and 99 (23.7%) stroke mimics. The most restrictive algorithm, defined as a TIA code in the main position had the lowest sensitivity (36.8%), but highest specificity (92.5%) and PPV (76.0%). The most inclusive algorithm, defined as a TIA code in any position with and without query prefix had the highest sensitivity (63.8%), but lowest specificity (81.5%) and PPV (68.9%). Sensitivity, specificity, PPV, and NPV were overall lower when using the 90-day diagnosis as reference standard.

CONCLUSIONS: Emergency department administrative data reflect diagnosis of suspected TIA with high specificity, but underestimate the burden of disease. Future studies are necessary to understand the reasons for the low to moderate sensitivity.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app