Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom.

Dysphagia 2018 Februrary
Interventional radiology procedures often involve lengthy exposure to fluoroscopy-derived radiation. We therefore devised a videofluoroscopic swallowing study (VFSS) procedure using a human phantom that proved to protect the patient and physician by reducing the radiation dose. We evaluated a new lead-shielding device and separately attached additional filters (1.0-, 2.0-, and 3.0-mm Al filters and a 0.5-mm Cu filter) during VFSS to reduce the patient's entrance skin dose (ESD). A monitor attached to the human phantom's neck measured the ESD. We also developed another lead shield (VFSS Shielding Box, 1.0-mm Pb equivalent) and tested its efficacy using the human phantom and an ionization chamber radiation survey meter with and without protection from scattered radiation at the physician's position on the phantom. We then measured the scattered radiation (at 90 and 150 cm above the floor) after combining the filters with the VFSS Shielding Box. With the additional filters, the ESD was reduced by 15.4-55.1%. With the VFSS Shielding Box alone, the scattered radiation was reduced by about 10% compared with the dose without additional shielding. With the VFSS Shielding Box and filters combined, the scattered radiation dose was reduced by a maximum of about 44% at the physician's position. Thus, the additional lead-shielding device effectively provided protection from scattered radiation during fluoroscopy. These results indicate that the combined VFSS Shielding Box and filters can effectively reduce the physician's and patient's radiation doses.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app