Comparative Study
Evaluation Studies
Journal Article
Add like
Add dislike
Add to saved papers

In silico evaluation of limited blood sampling strategies for individualized recombinant factor IX prophylaxis in hemophilia B patients.

Essentials Individual pharmacokinetic (PK) parameters can be obtained by limited sampling strategies (LSSs). Following 100 IU kg-1 rFIX, LSSs with 1 to 3 samples were evaluated in 5000 simulated subjects. For all LSSs, estimated individual PK parameters showed acceptable bias and precision. One sample between 10 min-3 h and two between 48 h-56 h showed best predictive performance.

SUMMARY: Background Patients with severe hemophilia B regularly administer prophylactic intravenous doses of clotting factor IX concentrate to maintain a trough level of at least 0.01 IU mL-1 in order to prevent joint bleeds. Assessment of individual pharmacokinetic (PK) parameters allows individualization of the recombinant factor IX (rFIX) dose. Aim To evaluate the predictive performance of limited sampling strategies (LSSs) with one to three samples to estimate individual PK parameters of rFIX. Methods Monte Carlo simulations were performed to obtain 5000 concentration-time profiles by the use of population PK parameters for rFIX from literature. Eleven LSSs were developed with one, two or three samples taken within an 80-h interval following administration of 100 IU kg-1 rFIX. Clearance (CL), half-life (t1/2 ), time to 1% and steady-state distribution volume (Vss ) were estimated for each simulated individual by the use of Bayesian analysis. Results For each LSS, average bias was small for CL (range - 1.5% to 1.4%), t1/2 (range - 4.5% to - 0.7%), time to 1% (range - 2.9% to 0%), and Vss (range - 3.7% to 0.3%). Imprecision for these parameters ranged from 6.4% to 11.9%, from 10.3% to 15.6%, from 7.3% to 10.9%, and from 9% to 20.1%, respectively. The best predictive performance was achieved with one sample taken between 10 min and 3 h and two samples taken between 48 h and 56 h after administration of rFIX. Conclusions This study demonstrates that limited sampling strategies, used for individualized dosing of rFIX in hemophilia B patients, can be developed and evaluated by in silico simulation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app